SPECTRA PRECISION FOCUS 2 SERIES TOTAL STATION USER GUIDE
4 –
Routine Measurements
50
1. From the
Angle
menu, press
[3]
to open the
RePt
screen.
The system sets the initial value of HR to 0.
2. Sight the first target point that is used in the repeat angle measurement. (i.e. backsight), and
press
[REC/ENT]
.
3. Use the horizontal clamp and tangent screw to sight the second target point (i.e. foresight). The
horizontal angle is now accumulated.
–
To end the repeat angle measurement, press
[ESC]
.
4. Press
[REC/ENT]
to save the horizontal angles and return to the initial repeat angle measurement
screen.
5. Repeat Step 3 through Step 4 as many times as needed.
When enough horizontal angle results have been accumulated, press
[MSR1]
or
[MSR2]
to take a
measurement to the foresight. The average horizontal angle is displayed. This value is fixed until the
process is finished or cancelled.
1. When enough horizontal angles results have been accumulated, take a measurement to the
foresight. First sight the backsight and press
[REC/ENT]
.
2. Sight the foresight, press
[MSR1]
or
[MSR2]
to measure the distance. The measured result is
displayed.
3. Press
[REC/ENT]
to record.