5.2 Assembly
Recommendation
Division 2
Division 1
Division 2 (1,5m)
Division 1 (2m)
Empty hose for powe cable
Earth
Distance equalization
Division 0
Division 0
Division 1
2,5m
See point 5.4
(Acc. to EN 13451)
≤45 mm
5.3 Electrical
Connection
WARNING!
Hazards resulting from electrical power are to be prevent-
ed.
VED and EVU specifications and by-laws of the local power supply
company must be followed.
The swimming pool and its protective area must be in accordance
with DIN VDE 0100-702.
A disconnecting device has to be installed to cut off the power sup-
ply (contact opening according to the conditions of the overvoltage
category III).
WARNING!
Voltage on the housing may cause electric shock.
Set the motor protection overload switch settings. Take the values
on the type plate into consideration.
Protect the electric circuit by means of an earth leakage switch:
residual current I
N
30 mA.
Only use cable types pursuant to the regional regulations.
Check that the min. diameter and length of the cable used is suita-
ble for the current drawn by the motor. See values on the motor ty-
pe plate.
Summary of Contents for BADUJET Riva
Page 34: ...10 Anlage I 34 DE VG 766 2330 061 05 2013 Abb 11 55 Abb 12 Abb 13 ...
Page 66: ...10 Appendix I 66 EN VG 766 2330 061 05 2013 fig 11 55 fig 12 fig 13 ...
Page 98: ...10 Annexe I 98 FR VG 766 2330 061 05 2013 OUVRIR FERMER Fig 11 55 Fig 12 Fig 13 ...
Page 130: ...10 Bijlage I 130 NL VG 766 2330 061 05 2013 OPEN DICHT afb 11 55 afb 12 afb 13 ...
Page 162: ...10 Impianto I 162 IT VG 766 2330 061 05 2013 APRIRE CHIUDERE Figura 11 55 Figura 12 Figura 13 ...
Page 227: ...10 Установка I 05 2013 VG 766 2330 061 RU 227 ОТКР ЗАКР Рис 11 55 Рис 12 Рис 13 ...