Swim Jet Combination Fitting - Manufacturers Warnings

4

WARNING: Before Installing this product, read and follow all warning notices and instructions which are included. 
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call 
(800) 223-8538 or visit www.usa.speck-pumps.com for additional copies of these instructions.
 

Important Safety Instructions

MUST BE INSTALLED by an experienced and qualified pool industry professional ONLY.

Attention Installer: This manual contains important information about installation, operation, and safe use of 
this product. This information should be given to the owner and/or operator of this equipment. Most states and 
local codes regulate the construction, installation and operation of pools and spas. It is important to comply with 
these codes, many which regulate the installation and use of this product.

1. DO NOT locate this fitting in seating areas or on the back rests for such seating areas.

2. This fitting should be mounted in the vertical pool wall only per manufacturer’s instructions.

3. All fittings and fasteners should be examined for damage or tampering before each use.

 

4. Any missing, broken, or cracked fittings must be replaced before using this product. Only genuine Speck 
replacement parts may be used.

5. Acceptable fittings/pipe sizes are listed on page 8 of this manual. No other sizes are permitted.

 

6. Never exceed the maximum flow rate stated on this product.

7. The anti-entrapment cover must be in place when using this product. DO NOT use this product if the cover is 
missing, broken, or loose.

8. The anti-entrapment cover (part# 8) should be replaced within 10 years from installation date.

9. Installation requires a Phillips screw driver. Hand tighten only. DO NOT use electrical or air drills.

10. Consult your physician before exercising with the Badu®Stream II or using the massage hose.

11. DO NOT permit children to use this product unless they are closely supervised at all times.

12. DO NOT remove any safety alert labels such as DANGER, WARNING, or CAUTIONKeep safety alert labels 
in good condition and replace missing or damaged labels.

13. Stay alert, watch what you are doing and use common sense. DO NOT use unit if you are tired and/or ex-
hausted.
 DO NOT use unit while under the influence of drugs, alcohol, or any medications

CAUTION: DO NOT increase pump size; this will increase the flow rate through the system and exceed the 
maximum flow rate stated on this product.
  

IMPROPER INSTALLATION OR USE OF THIS PRODUCT MAY PRESENT A RISK OF HAIR OR BODY ENTRAPMENT 

AND DROWNING. Install this equipment in accordance with the instructions provided.

As the manufacturer, Speck Pumps-Pool Products, Inc., hereby certifies that their Swim Jet Combination Fitting 
meets or exceeds the requirements of the Virginia Graeme Baker Pool & Spa Safety Act, VGB 2008 and ANSI/
APSP 16-2011 standards and safety regulations as set forth by the Consumer Products Safety Commission.

   “Read, and then keep these instructions for future reference”

Summary of Contents for Badu Stream II

Page 1: ......

Page 2: ...0 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Email technical usa speck pumps com Manufactured by Speck Pumps Jacksonville Florida USA...

Page 3: ......

Page 4: ...exceed the maximum flow rate stated on this product 7 The anti entrapment cover must be in place when using this product DO NOT use this product if the cover is missing broken or loose 8 The anti entr...

Page 5: ......

Page 6: ......

Page 7: ...for damage Open each carton and check the pump s jet housing s and control box for concealed damage such as cracks dents or a bent base If damage is found contact the shipper or distributor where the...

Page 8: ...s for two and three jet systems For two and three jet systems the jet housings must be installed as close to 10 center to center as possible for maximum performance DO NOT install the jet housing more...

Page 9: ...on and pressure lines as short and straight as possible If the pump is positioned further away then the pipe dimensioning has to be adapted so that almost loss free flowing is ensured BaduStream II He...

Page 10: ...g and 2 to 3 inches of plumbing stub out may be encased in gunite or concrete NOTE The BaduSteam assembly package contains all necessary parts for the installation of the unit into concrete gunite lin...

Page 11: ......

Page 12: ......

Page 13: ...Part 20 Air Regulator Gasket 60 x 11 x 2 mm Part 21 14 x 1 Screw Part 27 n n n n n n Make sure that the air regulator hose nipple part 14 is at the top and center of each jet housing Failure to do so...

Page 14: ...are installed using the eight 8 clamping ring screws part 9 2 9 3 or 9 4 The air regulator can be located in the tile above the water level or in the deck When tiling the pool adjust the air regulator...

Page 15: ...1 5 Nm or hand tight DO NOT use electrical or air drills NOTE The square cover part 8 will have an uneven appearance if the housing is not installed properly 4 For the air regulator assembly one 1 2 h...

Page 16: ...included with the touch button If a longer distance to the control box is required a junction box can be installed above the water line to splice additional cable as required NOTE The System ON OFF L...

Page 17: ...4 BLK 5 BLK 4 ORG 0 YEL 0 ORG 0 YEL 0 BLK 2 RED 2 RED 5 BLK 6 BLK 3 RED 3 BLK 0 BLK 1 BLK 0 RED 1 WHT 1 40A Shunt Tr p w AUX Switch C rcuit Breaker GFCI Module BLK 7 BLK 1 RED 6 BLK 6 BLK 5 BLK 3 RED...

Page 18: ...0 BLK 2 RED 2 RED 7 RED 7 RED 6 BLK 8 BLK 8 BLK 7 BLK 3 BLK 5 RED 3 RED 5 BLK 0 BLK 1 BLK 0 RED 1 WHT 1 50A Shunt Trip w AUX Switch Circuit Breaker GFCI Module BLK 3 BLK 6 BLK 5 BLK 7 RED 3 RED 5 RED...

Page 19: ...ill flash with an interval of 100ms Port 4 is on a schedule based on Time of Day Steady 5 with flashing dot The dot will flash with an interval of 100ms Port 5 is on a schedule based on Time of Day Fl...

Page 20: ...e tool breaks the surface of the water Then bring the two nozzles tools together to meet See Figure 16 Nozzle Adjustment Tools NOTE Though the nozzle adjustment tools are designed for outdoor use it i...

Page 21: ...is VGB 2008 compliant Do the covers come in different colors Yes The round covers can be ordered in gray or black The square cover is only available in black or white Does the air regulator come in di...

Page 22: ...Bad bearings Check for noise when shaft is turned by hand Motor will be very hot in bearing area when running Replace bearing 5 Motor runs hot These motors will run hot to the touch however this is n...

Page 23: ...Disassemble unit and correct 8 My ON OFF touch button is not working properly a Control Box b Wiring Check GFCI If green LED does not stay ON contact a certified electrician to diagnose control box c...

Page 24: ...7 11 1 11 2 10 4 13 1 2 12 12 3 8 9 1 27 15 16 14 5 Nozzle Adjustment Tool 31 9 2 9 3 9 4 18 16 14 17 21 18 20 19 26 23 24 25 22 24 6 Product Specification...

Page 25: ...REW CLAMPING RING PHILLIPS PAN M6 x 25mm SCREW CLAMPING RING PHILLIPS PAN M6 x 40mm SCREW SQ COVER EXT RING SLOT PAN M6 x 45mm SEAT NOZZLE SPACER NOZZLE 6 2mm SPACER NOZZLE 4mm GASKET CLAMPING RING GA...

Page 26: ...tem s 2 To the fullest extent permitted by law the Limited Warranty will be void and of no force or effect and Speck Pumps Pool Products Inc will have no liability responsibilities or obligations to B...

Page 27: ...SSIBILITY OR LIKELIHOOD OF SUCH DAMAGES OCCURRING WHETHER SUCH LIABILITY IS BASED ON CONTRACT TORT NEGLIGENCE STRICT LIABILITY PRODUCTS LIABILITY OR OTHERWISE AND EVEN IF ANY REMEDY STATED HEREIN FAIL...

Page 28: ......