background image

16

M017837080000 REV. January 19, 2011

2EZ Speed

TM

 Pool Motor with Programmable Control/Timer

M017837080000 REV. January 19, 2011

17

2EZ Speed

TM

 Pool Motor with Programmable Control/Timer

recommended Maintenance

WARNING

!

 Always disconnect electrical power 

at the fuse box or circuit breaker before handling 

electrical connections or performing maintenance 

on this unit. Allow the motor to come to a complete 

stop. This will allow the capacitors to discharge any 

residual voltage for safety. Double check to make  

sure power is oFF, and that it cannot be turned on 

while you are working on the equipment.

Periodically inspect the installation. 

•  Check for dirt accumulations, unusual noises or vibration, 

overheating, worn or loose couplings, high motor amps, 

poor wiring or overheated connections, and for loose 

mounting bolts or guards. 

•  Remove dirt accumulation, particularly in and around  

the ventilation openings on the motor by vacuuming.  

Dirt accumulations can cause motor overheating and  

a fire hazard. 

•  Do not use any type of solvents! Some solvents may have 

adverse interactions with the motor insulation, finish or 

bearing lubricants. Solvents are also highly flammable. 

•  This motor has permanently lubricated bearings –  

No further lubrication is recommended or required.

LIMITED WArrAnTy

Nidec Motor Corporation (hereinafter “Nidec”) extends the 

following LIMITED WARRANTY to the purchaser and to 

its customers (collectively referred to as the “Purchaser”) 

of the enclosed motor and components: the motor and 

components are free from defects in materials and 

workmanship under normal use, service and maintenance 

FOR A PERIOD OF 12 MONTHS FROM THE DATE OF 

ORIGINAL PURCHASE FROM NIDEC OR THE NIDEC 

DEALER/RETAILER, NOT TO EXCEED 24 MONTHS 

FROM THE DATE OF MANUFACTURE BY NIDEC. THE 

FOREGOING WARRANTY IS THE ONLY WARRANTY 

GIVEN AND NO OTHER WARRANTY IS PROVIDED, 

EXPRESS OR IMPLIED, INCLUDING WITHOUT 

LIMITATION, MERCHANTABILITY OR FITNESS 

FOR A PARTICULAR PURPOSE. Certain aspects or 

disclaimers are not applicable to consumer products, 

i.e., motors and components acquired by individuals and 

used for personal, family or household purposes (as 

distinguished from industrial or other purposes). Some 

states do not allow limitations on how long an implied 

warranty lasts, so the above limitation may not apply to 

you. This warranty gives you specific legal rights, and you 

may have other rights which vary from state to state.

Certain repairs or services are the responsibility 

of the Purchaser and the Purchaser is expected to 

pay for them. This warranty does not extend to any 

losses or damages due to misuse, accident, abuse, 

neglect, negligence, unauthorized modification or 

alteration, use beyond rated capacity, or improper 

installation, maintenance, application or use, including, 

without limitation, use in a manner contrary to the 

accompanying instructions or applicable codes. 

If within thirty (30) days after Purchaser’s discovery of 

any warranty defects within the above stated warranty 

period, Purchaser notifies Nidec or the dealer from whom 

the motor was purchased in writing, Nidec shall, at its 

option and as Purchaser’s exclusive remedy, repair or 

replace or refund the purchase price for, that portion of the 

motor and components found by Nidec to be defective. 

Failure by Purchaser to give such written notice within the 

applicable time period shall be deemed an absolute and 

unconditional waiver of Purchaser’s claim for such defects. 

Purchaser must write or call the dealer from whom the 

motor was purchased for directions regarding the shipment 

of the motor, with freight prepaid by the Purchaser, to 

an authorized service location for warranty service. 

If Purchaser is unable to contact the dealer to obtain 

sufficient instructions regarding the handling of the motor, 

Purchaser should write Nidec at the address below, giving 

the motor model number, the dealer’s name, address and 

number of dealer’s invoice; and describing the nature of 

the alleged defect. Arrangements for warranty service will 

then be made by Nidec. If the motor is damaged in transit, 

Purchaser should file a claim directly with the carrier.

IN NO EVENT, REGARDLESS OF THE FORM OF THE 

CLAIM OR CAUSE OF ACTION (WHETHER BASED 

IN CONTRACT, INFRINGEMENT, NEGLIGENCE, 

STRICT LIABILITY, OTHER TORT OR OTHERWISE), 

SHALL NIDEC’S LIABILITY TO PURCHASER OR 

ITS CUSTOMER EXCEED THE PRICE PAID BY 

PURCHASER FOR THE SPECIFIC MOTOR OR 

OTHER GOODS PROVIDED BY NIDEC GIVING 

RISE TO THE CAUSE OF ACTION. IN NO EVENT 

SHALL NIDEC’S LIABILITY TO PURCHASER OR ITS 

CUSTOMER EXTEND TO INCLUDE INCIDENTAL 

CONSEQUENTIAL OR PUNITIVE DAMAGES, WITH 

RESPECT TO CONSUMER PRODUCTS, SOME 

STATES DO NOT ALLOW THE EXCLUSION OR 

LIMITATION OF INCIDENTAL OR CONSEQUENTIAL 

DAMAGES, SO THE ABOVE LIMITATION OR 

EXCLUSION MAY NOT APPLY TO YOU. 

How to Lower utility Bills by using the 2EZ Speed

TM

 

Motor/Timer

Did you know that just by reducing the motor speed to low, 

you optimize your pool energy costs and still clean your 

pool? This is a primary advantage of the 2EZ Speed

TM

 

motor/timer! Your electric bill is based on the number of 

Kilowatt hours used in a typical billing cycle. The fewer 

Kilowatts used, the lower the bill! 

To calculate how much energy your current pool motor is 

using and to calculate your potential savings with the 2EZ 

Speed

TM

 motor/timer, visit 

www.nidec-motor.com/Pool 

and use our energy calculator. The calculator will show you 

how many hours to run your pump each day along with the 

appropriate speed settings for maximum energy savings 

while enabling the proper amount of daily flow to properly 

filter your pool.

IMPorTAnT noTE: 

Contact your local utility company to 

determine if there are times when usage may be prohibited, 

then program your 2EZ Speed

TM

 motor/timer to turn off or to 

run at a very low flow rate during these periods.

General Troubleshooting 

This chart suggests common answers to electric motor and control/timer issues. Refer to your pump manual for  

hydraulic guidance. When repetitive issues occur, Nidec recommends contacting your local pool and spa professional  

for technical assistance.

Symptom

Possible Causes

Corrective Action

Motor/Control  

fails to start

Blown Fuse or  

Open Circuit Breaker

Replace fuses with time delay type or reset breaker.

Incorrect Voltage to  

Motor/Control

Verify voltage to the motor terminals matches the nameplate 

voltage requirements. 207-253 Volts (60 Hertz) is the allowable 

voltage range for this product. Is there a timer, a controller, or a line 

switch? Are they in the ON position?

Improper terminal  

connections

Turn off power. Verify connections are per the nameplate 

connection diagram.

Blocked Pump or Shaft

Turn off power. Follow pump manufacturer’s instructions for 

dislodging foreign matter inside the pump. 

Motor/Control 

does not come up 

to full speed

Application issue

Call your pool service professional. The motor/control could  

be overloaded.

Low Voltage

Verify voltage to the motor terminals matches the nameplate 

voltage requirements. 

Motor/Control 

stalls during 

operation

Low Voltage

Verify voltage to the motor terminals matches the nameplate 

voltage requirements.  

Motor vibrates 

or is excessively 

noisy

Motor and Pump  

misalignment

Consult your pump manual for proper alignment instructions or call 

your pool service professional. Before taking any corrective actions, 

ensure the power is OFF.  

High Voltage

Verify motor/control voltage to the terminals matches the nameplate 

voltage requirements.  

Summary of Contents for BADU ECOM2/S90

Page 1: ...Installation Operating and Service Manual BADU EcoM2 S90 Swimming Pool Pump...

Page 2: ...cksonville FL 32256 USA Hours Monday Friday 8 00 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Manufactured by Speck Pumps Jacksonville F...

Page 3: ...fore using 8 TO REDUCE RISK OF ELECTRICAL SHOCK A copper bonding connector 8 AWG is provided for bonding the motor to all metal parts of the swimming pool spa or hot tub structure and to all electrica...

Page 4: ...both the suction and discharge line in the event that the pump must be removed for servicing 5 Before starting the pump for the first time remove the see through lid Turn lid ring counterclockwise to...

Page 5: ...pump Option 1 Drain all the water from the pump system equipment and piping Remove drain plugs DO NOT replace plugs Store the plugs in the empty strainer basket for winter Keep the motor covered and...

Page 6: ...on Repair leak Check suction pipe see through lid in place O ring clean Remove blockage or increase suction pipe size Make sure strainer tank is clean Are all suction valves fully open Disassemble pum...

Page 7: ...imited Warranty will be void and of no force or effect and Speck Pumps Pool Products Inc will have no liability responsibilities or obligations to Buyer or with respect to the pump and motor in the ev...

Page 8: ...ILITY PRODUCTS LIABILITY OR OTHERWISE AND EVEN IF ANY REMEDY STATED HEREIN FAILS OF ITS ESSENTIAL PURPOSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF SPECIAL INDIRECT INCIDENTAL EXEMPLARY...

Page 9: ...Save this instruction manual for future reference TWO SPEED POOL MOTOR WITH PROGRAMMABLE CONTROL TIMER These instructions cover the motor and the operation of the user interface timer controller whic...

Page 10: ...face Identification 7 9 Quick Start Programming 10 Detail Programming 11 13 How to Connect 14 Freeze Sensor 14 Locking the Keypad 15 Operating the 2EZ SpeedTM Pool Motor Control with other Equipment P...

Page 11: ...mming Supplied with default speed settings Just set the time and day of the week and the timer does the rest To customize your speed settings provide on and off times for Low and High Speeds Energy Ef...

Page 12: ...eing present at the motor and timer and potential shock hazard To connect power to the motor control timer unit refer to the connection diagram on the motor nameplate and the timer connection label In...

Page 13: ...CE Become familiar with the equipment and read all instructions thoroughly before installing or working on the equipment NOTICE The 2EZ SpeedTM motor control timer is properly packaged for shipment St...

Page 14: ...not run or puddle nearby Avoid splashing water on or near the motor control Contact qualified service person to repair leaky pipe joints or pump seals promptly Basic Motor Timer operation WARNING A pr...

Page 15: ...u navigation purposes and the keys for changing values For example while changing the time keys will move you from the hours to the minute s field while the keys will change the hour from 10 to 11 etc...

Page 16: ...aSu Program Press Enter to Con rm Set Clock Set on Time Set off Time override EnTEr 1 5 6 7 8 2 3 4 M017837080000 REV January 19 2011 2EZ SpeedTM Pool Motor with Programmable Control Timer user Interf...

Page 17: ...e select the current day of the week While in RUN mode the current day of the week will be illuminated based on the user setting Press Enter to Con rm is illuminated during the MENU mode This will rem...

Page 18: ...mming will resume Low Program override LoW SPEED o ErrIDE HIGH SPEED o ErrIDE High Program override 1 M017837080000 REV January 19 2011 2EZ SpeedTM Pool Motor with Programmable Control Timer A Setting...

Page 19: ...low speed to turn on Pressing ENTER will finalize your selections noTE In each Low or High Setting the user can select the off position when selecting the hour off resides between the hours of 12 and...

Page 20: ...nd your program settings will take precedence Functions of The Enter Button 1 Press to activate menu selection 2 Press to confirm changes to each menu selection ENTER can be pressed to exit a menu sel...

Page 21: ...verride or Low Speed override button 1 This button press will only take effect if the timer is enabled RUN STOP button is illuminated 2 After pressing the High Speed Override or Low Speed Override the...

Page 22: ...this same connection area near the motor terminal board assembly see connection label on motor control Permanent field wiring should be from a 2 pole device a device that disconnects two hot lines See...

Page 23: ...d stop during the programmed on and off times programmed on your 2EZ SpeedTM pool motor control Be aware of the backup power supply feature on the 2EZ SpeedTM pool motor control as other time clocks m...

Page 24: ...hen repetitive issues occur Nidec recommends contacting your local pool and spa professional for technical assistance Symptom Possible Causes Corrective Action Motor Control fails to start Blown Fuse...

Page 25: ...cific legal rights and you may have other rights which vary from state to state Certain repairs or services are the responsibility of the Purchaser and the Purchaser is expected to pay for them This w...

Page 26: ...Nidec Motor Corporation 8050 W Florissant Avenue St Louis MO 63136 www nidec motor com pool Pool Motor Product Service Hotline 1 800 566 1418...

Page 27: ......

Page 28: ......

Reviews: