background image

OWNER’S MANUAL

Swimming Pool Pump

READ THIS MANUAL CAREFULLY

BEFORE USING THE SPECK PUMP

Important Notice:

 

This manual contains important information about the installation, operation and safe 

use of this product. This information should be given to the owner and/or operator of this equipment. 

WARNING: This product must be installed and serviced by a qualified pool professional, and must conform to all 
national, state, and local codes. 

WARNING: Before installing this product, read and follow all warning notices and instructions which are included. 
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call 
(800) 223-8538 or visit www.usa.speck-pumps.com for additional copies of these instructions.

IMPORTANT SAFETY INSTRUCTIONS

1. 

READ AND FOLLOW ALL 

INSTRUCTIONS.

 

7. The unit must be connected only to a supply circuit 
that is protected by a ground-fault circuit-interrupter 
(GFCI). Such a GFCI should be provided by the installer 
and should be tested on a routine basis. To test the 
GFCI, push the test button. The GFCI should interrupt 
power. Push the reset button. Power should be 
restored. If the GFCI fails to operate in this manner, 
the GFCI is defective. If the GFCI interrupts power to 
the pump without the test button being pushed, a 
ground current is flowing, indicating the possibility of 
an electric shock. Do not use this pump. Disconnect the 
pump and have the problem corrected by a qualified 
service representative before using.

8. TO REDUCE RISK OF ELECTRICAL SHOCK, A copper 
bonding connector (8 AWG) is provided for bonding the 
motor to all metal parts of the swimming pool, spa, or 
hot tub structure and to all electrical equipment, metal 
conduit, and metal piping within 5 feet of the inside 
walls of a swimming pool, spa, or hot tub, when the 
motor is installed within 5 feet of the inside walls of 
the swimming pool, spa, or hot tub.

NOTE: To installer and/or operator of the Speck 
Swimming  Pool Pump; the manufacturer’s warranty 
will be voided if the pump is improperly installed and/
or operated.

9. 

SAVE THESE   

 

    

INSTRUCTIONS!

2. WARNING - To reduce the risk of injury, DO NOT 
permit children to use this product unless they are 
closely supervised at all times.

3. WARNING - Risk of Electrical Shock. Connect only 
to a branch circuit protected by a ground-fault circuit 
interrupter (GFCI). Contact a qualified electrician if you 
cannot verify that a circuit is protected by a GFCI.

4. WARNING - To reduce the risk of electric shock, 
replace any damaged cord immediately.

5. DO NOT install within an outer enclosure or beneath 
the skirt of a hot tub or spa.

6. CAUTION - This pump is for use with permanently-
installed pools and may also be used with hot tubs and 
spas if so marked. DO NOT use with storable pools. A 
permanently-installed pool is constructed in or on the 
ground or in a building such that it cannot be readily 
disassembled for storage. A storable pool is constructed 
so that it is capable of being readily disassembled for 
storage and reassembled to its original integrity.  

When installing and using this electrical equipment, 
basic safety precautions should always be followed, 
including the following: 

Summary of Contents for BADU ECOM2/S90

Page 1: ...Installation Operating and Service Manual BADU EcoM2 S90 Swimming Pool Pump...

Page 2: ...cksonville FL 32256 USA Hours Monday Friday 8 00 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Manufactured by Speck Pumps Jacksonville F...

Page 3: ...fore using 8 TO REDUCE RISK OF ELECTRICAL SHOCK A copper bonding connector 8 AWG is provided for bonding the motor to all metal parts of the swimming pool spa or hot tub structure and to all electrica...

Page 4: ...both the suction and discharge line in the event that the pump must be removed for servicing 5 Before starting the pump for the first time remove the see through lid Turn lid ring counterclockwise to...

Page 5: ...pump Option 1 Drain all the water from the pump system equipment and piping Remove drain plugs DO NOT replace plugs Store the plugs in the empty strainer basket for winter Keep the motor covered and...

Page 6: ...on Repair leak Check suction pipe see through lid in place O ring clean Remove blockage or increase suction pipe size Make sure strainer tank is clean Are all suction valves fully open Disassemble pum...

Page 7: ...imited Warranty will be void and of no force or effect and Speck Pumps Pool Products Inc will have no liability responsibilities or obligations to Buyer or with respect to the pump and motor in the ev...

Page 8: ...ILITY PRODUCTS LIABILITY OR OTHERWISE AND EVEN IF ANY REMEDY STATED HEREIN FAILS OF ITS ESSENTIAL PURPOSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF SPECIAL INDIRECT INCIDENTAL EXEMPLARY...

Page 9: ...Save this instruction manual for future reference TWO SPEED POOL MOTOR WITH PROGRAMMABLE CONTROL TIMER These instructions cover the motor and the operation of the user interface timer controller whic...

Page 10: ...face Identification 7 9 Quick Start Programming 10 Detail Programming 11 13 How to Connect 14 Freeze Sensor 14 Locking the Keypad 15 Operating the 2EZ SpeedTM Pool Motor Control with other Equipment P...

Page 11: ...mming Supplied with default speed settings Just set the time and day of the week and the timer does the rest To customize your speed settings provide on and off times for Low and High Speeds Energy Ef...

Page 12: ...eing present at the motor and timer and potential shock hazard To connect power to the motor control timer unit refer to the connection diagram on the motor nameplate and the timer connection label In...

Page 13: ...CE Become familiar with the equipment and read all instructions thoroughly before installing or working on the equipment NOTICE The 2EZ SpeedTM motor control timer is properly packaged for shipment St...

Page 14: ...not run or puddle nearby Avoid splashing water on or near the motor control Contact qualified service person to repair leaky pipe joints or pump seals promptly Basic Motor Timer operation WARNING A pr...

Page 15: ...u navigation purposes and the keys for changing values For example while changing the time keys will move you from the hours to the minute s field while the keys will change the hour from 10 to 11 etc...

Page 16: ...aSu Program Press Enter to Con rm Set Clock Set on Time Set off Time override EnTEr 1 5 6 7 8 2 3 4 M017837080000 REV January 19 2011 2EZ SpeedTM Pool Motor with Programmable Control Timer user Interf...

Page 17: ...e select the current day of the week While in RUN mode the current day of the week will be illuminated based on the user setting Press Enter to Con rm is illuminated during the MENU mode This will rem...

Page 18: ...mming will resume Low Program override LoW SPEED o ErrIDE HIGH SPEED o ErrIDE High Program override 1 M017837080000 REV January 19 2011 2EZ SpeedTM Pool Motor with Programmable Control Timer A Setting...

Page 19: ...low speed to turn on Pressing ENTER will finalize your selections noTE In each Low or High Setting the user can select the off position when selecting the hour off resides between the hours of 12 and...

Page 20: ...nd your program settings will take precedence Functions of The Enter Button 1 Press to activate menu selection 2 Press to confirm changes to each menu selection ENTER can be pressed to exit a menu sel...

Page 21: ...verride or Low Speed override button 1 This button press will only take effect if the timer is enabled RUN STOP button is illuminated 2 After pressing the High Speed Override or Low Speed Override the...

Page 22: ...this same connection area near the motor terminal board assembly see connection label on motor control Permanent field wiring should be from a 2 pole device a device that disconnects two hot lines See...

Page 23: ...d stop during the programmed on and off times programmed on your 2EZ SpeedTM pool motor control Be aware of the backup power supply feature on the 2EZ SpeedTM pool motor control as other time clocks m...

Page 24: ...hen repetitive issues occur Nidec recommends contacting your local pool and spa professional for technical assistance Symptom Possible Causes Corrective Action Motor Control fails to start Blown Fuse...

Page 25: ...cific legal rights and you may have other rights which vary from state to state Certain repairs or services are the responsibility of the Purchaser and the Purchaser is expected to pay for them This w...

Page 26: ...Nidec Motor Corporation 8050 W Florissant Avenue St Louis MO 63136 www nidec motor com pool Pool Motor Product Service Hotline 1 800 566 1418...

Page 27: ......

Page 28: ......

Reviews: