Please heed the installation and operation manual of the pump used together
with the BADU QUICK.
When installed in a closed room, for example a cellar, a drainage connected to
the sewers must be foreseen.
The size of the drainage must be calculated according to the following criteria:
– size of the swimming pool
– volume flow rate
6. start-up
6.1
Close the ball valves in the suction and pressure lines. Unscrew the pump lid,
fill the pump and close the lid again.
Start the pump and open the valves in the suction and pressure lines. The
pump will now prime automatically. The priming time depends on the volume of
air in the suction line. The BADU QUICK will vent itself automatically.
6.2 Please heed the installation and operation manual of the pump used together
with the BADU QUICK.
7. Maintenance
7.1
The strainer basket in the strainer tank of the pump must be emptied periodical-
ly. A full or dirty strainer will impair the pump’s flow rate and will cause noise.
Never operate the BADU QUICK without the pump’s strainer basket in place,
otherwise the BADU QUICK may become clogged.
Please heed the installation and operation manual of the pump used together
with the BADU QUICK.
7.2 cleaning the filter cartridges
Once the needle of the pressure gauge reaches the red maximum area, the fil-
ter elements must be cleaned because the pump’s flow rate will have decreas-
ed so far that the flow will be insufficient for an adequate filtration of the pool.
7.3 Maintenance instructions
1. Shut the pump down.
2. Close ball valves in the suction and pressure lines.
3. Unscrew the air relief plug (5), for example using a coin.
4. Loosen the lower part (14) with the key and unscrew it.
5. Remove the filter cartridges from the upper part and clean.