10/2012
VG 766.2100.060
27
3 The volumetric flow and the
priming time period are changed
using the arrow buttons.
The "up/down" buttons are used to
change the values. The "left/right"
buttons are used to toggle
between the fields.
4 Use the "Enter" button to confirm
all settings when they are made.
Setting the timer programs (Custom Flow 1...4)
1 The
programming
interface
is
accessed by pressing the
"Program Menu" button. Select the
timer programs – Custom Flow 1 –
using the arrow button. Press the
"Enter" button to edit them.
Settings can only be made when
the pump is in stand-by mode.
2 When "Custom Flow" flashes,
toggle between the four programs
using the arrow buttons (up/down)
and set the run time and the
volumetric flow using the arrow
buttons (left/right).
Volumetric flow
: (0), 30-100%
Timer period: 10-249 minutes