USER’S MANUAL
EN
18
7.6
INSTALLATION – MMA WELDING
Before connecting hardware and shielding gas to the device, make sure that the device is discon-
nected from power source and switch
10
is in the OFF position.
The
welding polarity depends on the type of electrodes used. Before connecting the cables refer to
the requirements specified by the manufacturer of electrodes.
1.
Connect electrode cable plug into SK socket
8
or
9
.
2.
Connect return cable plug into appropriate SK socket
8
or
9
.
3.
Connect earth clamp into workpiece.
4.
Connect the welder into power supply in accordance with appropriate guidelines
(see 7.4)
.
5.
Turn on the welder by setting power switch
10
in the ON position.
6.
The device is ready to weld.
Control cable
Work cable
Electrode holders
Input 400V AC
Weld material
1
Current display
2
Voltage display
3
Voltage adjustment knob MMA
4
Burning the end of the wire
(MIG 4T)
5
Inductance adjustment knob
6
Switch MIG / MMA
7
Operation mode 2T/4T
8
Gas test
9
Power indicator
10
Warning indicator
7.7 DEVICE CONTROL PANEL – USING
7.7.1 Function panel description (source)
1
3
9 10
4
5
6
7
8
2