Spartus ProMIG 420H User Manual Download Page 2

WELDING EQUIPMENT SUITABLE FOR TODAY’S NEEDS

Thank you for purchasing our product!

You have made a right choice. Plasma welding and welding processes are 

carried out in difficult conditions that expose welding equipment to extreme 

tests of its strength. Only high quality equipment can ensure required reliability 

and performance during realization of the above-mentioned processes. SPAR-

TUS® products are characterized by precisely such features: they are primarily 

reliable and durable, but they are also versatile. We listen carefully to clients’ 

needs. Therefore, our offer covers such a wide assortment of products. Thank 

you very much for your trust in our company. We would like to invite you to 

familiarize yourself with the remaining products and offer at www.spartus.

info or directly at a local distributor of SPARTUS® products.

Summary of Contents for ProMIG 420H

Page 1: ...User s manual Semiautomatic welder SPARTUS ProMIG 420H 420HW...

Page 2: ...nd performance during realization of the above mentioned processes SPAR TUS products are characterized by precisely such features they are primarily reliable and durable but they are also versatile We...

Page 3: ...Fire or explosion hazard 5 1 7 Other hazards 6 1 8 Other informations 6 1 9 Symbols used in instructions 7 2 ELECTROMAGNETIC FIELD EMF 7 3 ELECTROMAGNETIC COMPATIBILITY EMC 7 3 1 General informations...

Page 4: ...ding operations are expected to be carried out All equipment should be placed so that it does not present a hazard in passageways on ladders or stairways etc Falling objects can cause injuries or kill...

Page 5: ...n dazzle and impair vision infrared heat radiation can damage skin and eyes Such radiation can be direct or reflected from surfaces such as bright metals and light colo ured objects 1 3 1 Eye and face...

Page 6: ...st draught to keep vapours and gases away from the breathing zone When welding is carried out in a confined space operators should only be permitted to weld when other persons who have been instructed...

Page 7: ...ible place The surroundings of the work should be observed for an adequate period after its termination Hot spots and immediate surroundings should be observed until their temperature has dropped to n...

Page 8: ...er The welding wire tip may be sharp Never aim the burner tip of the welding torch at your face eyes or other people 1 7 4 Moving elements can be dangerous All protective elements and device housing s...

Page 9: ...ices for example cardiac pacemakers Persons with implanted medical devices such as cardiac pacemakers are obliged to consult a doctor before starting to weld plasma cutting and to exercise special cau...

Page 10: ...at other equi pment being used in the environment is compatible This may require additional protection measures h the time of day that welding or other activities are to be carried out The size of the...

Page 11: ...dicated to specialized industrial applica tions Machines are ready to work in toughest conditions 5 1 PURPOSE OF USE SPARTUS ProMIG 420H i 420HW welding devices are designed for Manual Metal Arc MMA w...

Page 12: ...not designed to be used outdoor during precipitation if it is not covered 6 2 TECHNICAL PARAMETERS OF DEVICE SPARTUS ProMIG 420H SPARTUS ProMIG 420HW Input 3 x 400V 10 50 60 Hz Welding current MIG A 8...

Page 13: ...ive the risk and avoid hazards during use of the product IEC 60204 1 7 1 PROPER COOLING The unit should be placed stable on a dry and flat surface Avoid too much slope and slippery surfaces Check regu...

Page 14: ...N 12 6 Control panel 7 Connection cable set control socket 8 SK socket 9 SK socket 10 ON OFF switch 11 Gas heater socket 12 Fan 13 Water cooler connector 14 Power cable 400V 15 Rating plate 8 7 10 11...

Page 15: ...ction Output 21 Connection cable set control socket 22 Connection cable set current socket 23 Gas inlet 24 Coolant Connection Output 25 Coolant Connection Input 26 Wire inlet guide 27 Tension adjustme...

Page 16: ...t with plug A P8 P6 P7 P3 P2 P1 P1 P3 P2 P5 P4 P7 P6 P8 P10 P9 P6 Control plug B P7 Current plug B P8 Gas hose P9 Hose liquid cooling input with plug B P10 Hose liquid cooling output with plug B 7 3 4...

Page 17: ...It is forbidden bridging PE and N cables it may cause serious risk of electric shock In some cases colours of power cords may vary from those shown on diagram For example when the device has a four wi...

Page 18: ...e end of cooling hose P9 into cooler and wire feeder 30 5 Only for ProMIG 420HW Connect the end of cooling hose P5 into wire feeder 25 Connect the end of cooling hose P10 into cooler and wire feeder 3...

Page 19: ...ce approx 30mm beyond the torch outline release the button INCH FEEDING 7 Assemble welding wire into liner gas nozzle contact tip 8 Cut off the end of wire properly 7 5 6 Device installation 1 Connect...

Page 20: ...g into appropriate SK socket 8 or 9 3 Connect earth clamp into workpiece 4 Connect the welder into power supply in accordance with appropriate guidelines see 7 4 5 Turn on the welder by setting power...

Page 21: ...Check if cooling fan is working properly Make sure that all vents are not obstructed At least once a month Regularly remove dust from inside of the machine Use for this compressed air The pressure sh...

Page 22: ...he control circuit Excessive heating of MIG gun Contact tip is not properly fastened or tightened Too high welding current in relation into MIG gun capacity Unstable arc welding Contact tip is worn or...

Page 23: ...igh quality production excellentparametersandergonomics thesearefea turesoftheSPARTUS Masterseriesofdevices which werecreatedwithdemandingweldingjobsinmind Precision functionality excellent parameters...

Page 24: ...Videopresentation of products Subscribe to the channel SPARTUS INFO...