GB
GB
39
6.3 MAINTENANCE
The door seal should be checked regularly. This seal must be replaced if neces-
sary (in case of wear, breakage, etc.). The combustion chamber liner is made of
natural products and must therefore be checked at regular intervals.
As long as the combustion chamber liner maintains the position in the
combustion chamber and does not break, it is fully functional. A crack in
the fireclay brick is therefore no need for a complaint. To ensure proper
functioning, it is essential that an annual (if possible before the heating
season) maintenance of the stove be carried out by a specialist!
Furthermore, the following applies to room air independent stoves:
Proper door seal is an essential item for room-air-independent operation of
the stove. Check the seal for optical characteristics (pressure, wear, bulges)
at least once per heating season and replace it immediately if damaged.
The fireplace must never be modified! Only original spare parts that have
been approved by the manufacturer may be used! If you have any questions,
please contact your specialist dealer.
6.3.1 LUBRICATION MANUAL FOR DOOR LATCHES
WITH SMARTCLOSE
Stoves with SmartClose door locking mechanisms must be lubricated at reg-
ular intervals to assure problem-free operation (once per heating season).
For this purpose, the scope of delivery of
each fire area includes a tube of special
stove lubrication compound.
This lubricating compound is applied to
facilitate ease of movement of heavy fire
doors, and to prevent noise caused by
opening and closing those fire doors. The
lubricating compound must be applied at
least once a year to the spring connection
on the SmartClose and its asso-
ciated roller. With fire areas used
frequently or very frequently, it
may be necessary to shorten this
lubrication interval. Depending
on the type of stove, the door
lock springs may be located
below and/or above the fire door.
In order to lubricate the lock,
you may use a standard cotton
swab/Q-tip as an aid.
To apply the lubricant compound,
proceed as follows:
Open and secure the fire door; Apply a little lubricant compound to the cotton
swab (see Fig. 1) and use it to coat the spring support on the door lock; Turn
the locating roller on the body of the stove during this application process
(see Fig. 2). Open and close the fire door a few times and, if necessary, apply
the lubricant compound once again.
Caution: Ensure that no
copper lubricant compound
makes contact with clad-
ding parts or similar items!
Remove dirt and grime
straightaway with a cotton
cloth. Never operate the
equipment during interven-
ing periods.
Sp
rin
g sea
t
Take-up rollers