about 15-20 minutes.
For better performance of the Senso M H
2
O / H
2
O Piko, wood should be refilled
in time in order to avoid an excessive drop in the flue gas temperature.
4. COMBUSTION
4.1 INITIAL COMMISSIONING
The stove must only be installed and set up by a specialised company. The
initial commissioning must only be executed by an expert employee of the
installation company. A certificate confirming proper installation and proper
adjustment / function of all control components and safety components must
be given to the owner / operator of the system (see „10. Commissioning
A
B
A
B
A =
water heat exchanger
weak performance
B =
water heat exchanger
maximum performance
Senso M H
2
O
Piko H
2
O
3.4 TYPE PLATE
The type plate is located both on your guarantee certificate, as well as on
your stove at the back or under the ash drawer. It includes technical data
and information. The type plate must not be removed as it confirms the
testing of the stove and is required for the acceptance procedure and annual
inspections by the chimney sweep.
3.5 OPERATION OF THE WATER HEAT EXCHANGER
SENSO M H
2
O / PIKO H
2
O
Operation of the water heat exchanger is done with the lever on the right
side on the back (see figure). This switches between heating-up/refuelling and
combustion. Intermediate positions of the lever are not provided.
Senso M H
2
O
Heating-up and combustion phase: The lever is at the top
(A).
The flue gases
are not passed through the heat exchanger of the Senso M H
2
O. Therefore, the
chimney draught can develop quickly and effectively.
Combustion position: The lever is pushed all the way down
(B).
Now all flue
gases are passed through the water heat exchanger of the Senso M H
2
O. This
position should only be chosen when the stove has fully heated up, the fuel
has started burning fully and embers have formed. Normally, this happens after
about 15-20 minutes.
Piko H
2
O
Heating-up and combustion phase: The lever is at the bottom
(A).
The flue
gases are not passed through the heat exchanger of the Piko H
2
O. Therefore,
the chimney draught can develop quickly and effectively.
Combustion position: The lever is pushed all the way to the top (
B
). Now all
flue gases are passed through the water heat exchanger of the Piko H
2
O. This
position should only be chosen when the stove has completely heated up, the
fuel started to burn and embers have formed. Normally, this happens after