Spartherm Cubo L Installation And Operating Manual Download Page 38

GB

 38

ORDER NUMBERS FOR REPLACEMENT FIRECLAY

Item

Designation

Cubo / 

Piko 

S, M, L

Cubo / 

Piko 

S, M, L 

RLU

Piko H2O

Redoro  

S/M

Stovo 

S/M

Stovo S  

plus

Stovo L

Stovo L  

plus

Senso S

Senso S  

RLU

Senso L 

/ RLU, 

Senso M 

H2O

Sino L

Sino City 

/ RLU, 

Noto

Moro

Passo 

XS / 
RLU

Passo 

S, M, L / 

RLU

Single stone, fireclay

1

Flagstone, front

-

-

-

-

1018809

1041909

1018809

1041909

1033333 1015039** 1033858

1033858

1033858

1033291

1019862

1033860

2

Flagstone, back

-

-

-

-

1018810

1041910

1018810

1041910

1033334 1015040** 1033859

1033859

1033859

1033292

1019863

1033861

3

Flagstone, left

1030945 1015034** 1012634* 1030945

-

-

-

-

-

-

-

-

-

-

-

-

4

Flagstone, right

1030947 1015035** 1012634* 1030947

-

-

-

-

-

-

-

-

-

-

-

-

5

Deflector plate

1015038

1015038

1012260

1015038

1018816

1041915

1018816

1041915

1015047

1015047

1012254

1012254

1012254

1033300

1019870

1012385

6

Back wall stone, top

-

-

-

-

1018813

1018813

1018813

1018813

1015046

1015046

1012253

1012253

1012253

-

1019869

1012383

7

Back wall stone, bottom

-

-

-

-

1018812

1018812

1018812

1018812

1015045

1015045

1012252

1012252

1012252

-

1019867

1012384

8

Sidewall stone, left front

-

-

-

-

-

1041914

-

1041914

1015041

1015041

1012250

1012250

1012250

-

-

-

9

Sidewall stone, left back

-

-

-

-

-

-

1012248

-

1015043

1015043

1012248

1012248

1012248

-

-

-

10

Sidewall stone, right front

-

-

-

-

-

1041914

1012251

1041914

1015042

1015042

1012251

1012251

1012251

-

-

-

11

Sidewall stone, right back

-

-

-

-

-

-

1012249

-

1015044

1015044

1012249

1012249

1012249

-

-

-

12

Sidewall stone, left

1015036

1015036

1012258

1015036

1018814

1041912

-

-

-

-

-

-

-

1033293

1019864

1012382

13

Sidewall stone, right

1015037

1015037

1012259

1015037

1018815

1041911

-

-

-

-

-

-

-

1033294

1019865

1012381

14

Edge stone

-

-

-

-

-

-

-

1041913

-

-

-

-

-

-

-

-

15

Back wall stone

-

-

-

-

1018811

1041920

-

1041908

-

-

-

-

-

1033295

-

-

Complete set, fire clay

Fireclay set, complete, without baffle plate

1033437 1015104** 1031728* 1033437

1024757 1015105** 1024758

1041921

1033336 1015105** 1042175

1042175

1042175

1033299

1024759

1033863

Accessories

Grate (to insert)

-

-

1006404

-

-

-

-

-

-

-

-

-

-

-

-

-

Hinged grating

1019059

-

-

1019059

1019059

1019059

1019059

1019059

1019059

-

1019059

1019059

1019059

1019824

1019059

1019824

Ash drawer

1041842

-

1041843

1041842

1041844

1041934

1041844

1041934

1041847

-

1041846

1041845

1041848

1041850

1041851

1041849

* insertion grid
** no grate

Summary of Contents for Cubo L

Page 1: ...Installation and Operating Manual Stoves selection...

Page 2: ...lso engender feelings of comfort and security To ensure this we encourage you to read the operating manual carefully so that you can become familiar with your stove and its accessories quickly and tho...

Page 3: ...S Thermatik Mini 27 3 3 Function of the rotary base 28 3 4 Type plate 29 3 5 Operation of the water heat exchanger Senso H2O PIKO H2O 29 4 Combustion 29 4 1 Initial commissioning 29 4 1 1 Combustion...

Page 4: ...tion Note down any possible damage on your delivery note and then please 1 GENERAL INSTRUCTIONS Please consult your district master chimney sweep before assembling and installing the stove He will adv...

Page 5: ...German Federal State LBO Regional building regulations and fire regulations of VKF VKF Switzerland LRV Switzerland 1 BlmschV Erste Verordnung zur Durchf hrung des Bundes Immis sionsschutzgesetz First...

Page 6: ...771 would be hazardous in the event of ignition or explosion Room air independent stoves can be placed in rooms apartments or uti lization units of comparable size from which air can be sucked out usi...

Page 7: ...L 2015 1382 1980 Piko Piko S 973 1712 Piko M L 1113 1852 Piko M L with log storage compartment 1113 1852 Piko S RLU 973 1739 Piko M RLU 1113 1852 Piko M RLU with log storage compartment Piko L RLU 125...

Page 8: ...lue gas connection at the top when delivered Depending on the model the flue gas connection position can be changed so that it is aligned to the back to the side or around corners Follow these install...

Page 9: ...m air independent in different ways 2 3 2 1 ROOM AIR DEPENDENT Your stove draws the combustion air from the installation area room air depend ent operation Ensure that the installation area is adequat...

Page 10: ...f it has been ensured that the fireplace can only be operated with opened fas tening by special safety equipment The cross section must not be narrowed by a fastening or a grille This measure is not n...

Page 11: ...in its final position 2 Screw in the adjustable feet to adjust the stove to its nominal height When lowering it the SQC connecting piece makes contact with the base unit and encloses the supply openin...

Page 12: ...e Date of construc tion Order no C in mm Bore 100 mm for a combus tible mounting wall for a mounting wall that is not to be protected Senso S from 11 2014 1033724 308 258 Passo XS 1033726 286 286 Pass...

Page 13: ...untersunk screws 2 3 2 3 ROOM AIR INDEPENDENT The RLU stoves have been developed for use with residential ventilation systems for a vacuum range of up to 8 Pa in the installation area and can be opera...

Page 14: ...r to be protected e g timber frame construction must be protected from temperatures 85 C Before installing the stove it is necessary to evaluate the mounting walls If the type of mounting wall cannot...

Page 15: ...ng wall to the beginning of the area of direct radiant heat E of the front panel In stoves with curved front pane or a wide area of direct radiant heat the minimum wall distance A must be adjusted to...

Page 16: ...brennbar z B Sessel Front pane rotatable Bodenbelag C Strahlungsbereich A D B brennbar z B Sessel Fig 19 Front pane flat Strahlungsbereich A B C Bodenbelag D brennbar z B Sessel Fig 20 Corner pane Rad...

Page 17: ...30 50 Cubo S Cubo S RLU 10 10 10 5 80 80 50 x 30 50 Cubo M Cubo M RLU 10 10 10 5 80 80 50 x 30 50 Cubo L Cubo L RLU 10 10 10 5 80 80 50 x 30 50 Redoro S M 10 10 10 5 80 80 50 x 30 50 Stovo S 31 20 16...

Page 18: ...be insulated according to the respective regulations The connecting line must always be mounted in such a manner that it is possible to clean the connecting line at any time This must be ensured throu...

Page 19: ...GB 19 Stovo M A Remove pull top plate for ward and remove upwards B insert C insert D fit Senso L Senso L RLU Heat storage stones optional A open B insert C close Redoro M A B C A remove B insert C f...

Page 20: ...h can be routed to the back and the side with the flexible attachment kit The connections have transport caps and brass stops for transport purposes This must be removed prior to installation The conn...

Page 21: ...inoperable Moreover all necessary safety devices must be integrated in the entire system in such a manner that safe operation is ensured A separate safety valve must also be installed if such a safet...

Page 22: ...as a controller if a switch on temperature of the pump between 60 C and 68 C is guaranteed The maximum contact load of the thermal pump control at alternating current 250 V AC is approximately 10 2 5...

Page 23: ...ions Integration of the Senso M H2O Piko H2O can be carried out based on the diagram on the next page A buffer tank must be connected up German legislation 1st and 2nd BImSchV mandates the design of v...

Page 24: ...ank from an assumed 30 C to 60 C a theore tical heat quantity of 94207 kJ is required losses or heat withdra wals in the system have not been taken into account This heat quantity corresponds to appro...

Page 25: ...orresponds to the effective return temperature at the inlet of the water heat exchanger is recorded and set to the desired value We recommend the use of a return riser riser of the type LTC 200 from E...

Page 26: ...tage Degree of protection IP 50 The S Thermatik Mini combustion control is pre set to your stove ex factory Changes to the control parameters must only be carried out by an installer stove fitter or t...

Page 27: ...S Ther matik Mini mode must be carried out manually using a mechanical release changeover of the selector switch to manual mode The selector switch is located on the supply air box and is visible whe...

Page 28: ...y base can only be executed at the top and must be stated when ordering The stove is can rotate through 180 90 to the left and right respectively Sino L 120 rotatable 60 to the right and left respecti...

Page 29: ...ER SENSO M H2O PIKO H2O Operation of the water heat exchanger is done with the lever on the right side on the back see figure This switches between heating up refuelling and combustion Intermediate po...

Page 30: ...and operating instructions must always be kept in the vicinity of the Senso M H2O Piko H2O where they can be easily accessed Contaminated condensate exiting the combustion chamber liner may con tamina...

Page 31: ...on This always depends on experience and on prevailing conditions on location 12 Do not open the door forcefully or gases may enter your living room through a suddenly produced negative pressure At fi...

Page 32: ...The room heating capability used to be quoted in accordance with the DIN 18893 standard most recent edition being August 1987 so is no longer a meaningful indicator for modern houses constructed afte...

Page 33: ...eap and it quickly pays for itself Do not use any other fuels It follows from this that it is not permitted to burn painted or plastic coated wood Fibreboard or wood that has been treated with timber...

Page 34: ...dd to the fire to suit your heating requirements You can check that combustion in your stove is clean and relatively free of pollutants in the following way The ash should be white If the ash is dark...

Page 35: ...lable cleaning agent for fireplace glass Use dry cloth to wipe No scouring Please do avoid that excess cleaning agent enters between door frame and glass panel This might cause the hardening of the se...

Page 36: ...ified complaint The lining is exposed to very high loads A tension or expansion crack is not a matter for concern and is not a functional deficiency However cracked and combustion chamber lining parts...

Page 37: ...GB GB 37 Passo S M L RLU Passo XS RLU Senso S RLU Stovo L Stovo L plus 0 Senso S RLA Senso L Senso M H2O Sino L Sino City Noto Senso L RLU Sino City RLU Moro Moro RLU...

Page 38: ...015045 1012252 1012252 1012252 1019867 1012384 8 Sidewall stone left front 1041914 1041914 1015041 1015041 1012250 1012250 1012250 9 Sidewall stone left back 1012248 1015043 1015043 1012248 1012248 10...

Page 39: ...eg ular intervals to assure problem free operation once per heating season For this purpose the scope of delivery of each fire area includes a tube of special stove lubrication compound This lubricati...

Page 40: ...chamber and should be cleaned off from there at least 2 times per season SENSO M H2O Because the water heat exchanger cools down the flue gases of the Senso 6 3 2 MAINTENANCE OF THE WATER HEAT EXCHAN...

Page 41: ...leaning After inserting it it must be twisted about 5 times to the right and left to the stops approximately 20 angle of rotation A remove wing nuts remove cleaning cover B remove deposits in the pipe...

Page 42: ...open up the combustion air flow rate fully to bring the fireplace unit up to operating temperature The seating of a gasket is not perfect Check all seals e g open the fire door and press the seal ful...

Page 43: ...eplace installer or chimney sweep Smoke escapes when adding wood Air extracting equipment is switched on e g kitchen extractor fan Ensure that all air extracting equipment is switched off Wood added p...

Page 44: ...discharge safety device pay attention to the minimum flow rate Radiators do not warm up Radiators that are not located in the instal lation room are cold Close radiator thermostats when the set room...

Page 45: ...components such as fans rotational speed controllers the manufacturer s original spare parts all items purchased as additional extras and all safety appliances Spartherm Feuerungstechnik GmbH offers...

Page 46: ...shall automatically be extended where claims made in respect of these warranty provisions result in the repair or replacement of defec tive equipment 8 8 SPARE PARTS Only the manufacturer s own compon...

Page 47: ...o liability in respect of any errors made Technical data SENSO M H2O PIKO H2O Water heating output approx 5 0 kW 4 6 kW Perm working overpressure 3 0 bar 3 0 bar Max perm flow temperature1 105 C 105 C...

Page 48: ...56 Mass flow of flue gas at NW g s 4 9 4 9 4 9 4 9 4 9 4 9 4 9 8 6 4 9 Flue gas temperature on the flue gas outlet C 325 325 325 325 325 325 325 215 325 Min supply pressure at NW Pa 12 12 12 12 12 12...

Page 49: ...ass flow of flue gas at NW g s 4 9 4 9 4 9 4 9 4 9 4 9 4 9 4 9 4 71 Flue gas temperature on the flue gas outlet C 325 325 325 325 325 325 325 325 273 Min supply pressure at NW Pa 12 12 12 12 12 12 12...

Page 50: ...48 130 Mass flow of flue gas at NW g s 3 6 4 71 4 71 3 6 6 12 6 2 6 7 6 3 4 4 7 5 Flue gas temperature on the flue gas outlet C 353 273 273 353 260 250 317 330 335 422 Min supply pressure at NW Pa 12...

Page 51: ...ourable approx m3 48 130 82 48 65 130 65 130 65 130 Mass flow of flue gas at NW g s 3 9 7 2 5 5 7 22 5 8 8 0 5 8 8 0 5 8 8 0 Flue gas temperature on the flue gas outlet C 337 255 340 255 312 387 312 3...

Page 52: ...perating pressure checked yes no yes no Enter temperatures between insert and return flow boost Return flow temperature in C Flow temperature in C The stove operator has been instructed regarding oper...

Page 53: ...h Year SPARTHERM The global brand for your lounge Service hotline 0180 594 41 94 14 cents minute incl VAT from a German landline max 42 cents minute incl VAT from a German mobile network Spartherm Feu...

Reviews: