NOTE : The measured zone dimensions are limited by walls and fixed partitions.
Above are the measured zone dimensions for the bathtub.
Zona 2
Zona 2
Zona 1
Zona 0
DESCRIPTION OF THE ZONES
ZonE 0
Zone 0 is the interior of the bathtub including all the recesses of the walls and floors.
ZonE 1
Zone 1 is limited by: • zone 0
• An horizontal plan 2m from the rim of the basin
• The floor of the surface expected to be occupied by persons
• The vertical plan 2.5m above the floor of the surface
ZonE 2
Zone 2 is limited by:
•
An horizontal plan 1.5m from the rim of zone 1
•
The floor or surface expected to be occupied by persons
EN
PLEASE READ THE SAFETY INSTRUCTIONS CAREFULLY BEFORE USING
THE PRODUCT.
• This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and un-
derstand the hazards involved.
• Children shall not play with the appliance. Cleaning and user main-
tenance shall not be made by children without supervision.
• If the supply cord is damaged, it must be replaced by the manufac-
turer, its service agent or similarly qualified persons in order to avoid
a hazard.
• Parts containing live parts, except parts supplied with safety ex-
tra-low voltage not exceeding 12 V, must be inaccessible to a person
in the bath.
• Earthed appliances must be permanently connected to fixed wiring.
• Parts incorporating electrical components, except remote control
devices, must be located or fixed so that they cannot fall into the bath.
• The appliance should be supplied through a residual current device
(RCD) having a rated residual operating current not exceeding 30 mA.
• Means for disconnection having a contact separation in all poles
must be incorporated in the fixed wiring in accordance with the wiring
rules.
• Electrical installation shall comply with the national wiring rules
(Thanks to refer to the below drawing for installation)
• Respect the installation rules, in particular, check that the different
parts are installed in the correct zone and that equipotential bonding
is carried out.
SAFETY INSTRUCTIONS
8