Installation Requirements
In the United States, it is required that this machine
be installed in compliance with National Electrical
Code (NEC) ANSI/NFPA 70-1987 to practically
safeguard persons and property from hazards arising
from the use of electricity. The unit must be installed
into a properly grounded receptacle for the cord and
plug provided. The machine is labeled with detailed
electrical specifications. Refer to wiring diagrams for
correct power connections.
Electrical requirements
Refrigerant requirements
Spaceman USA requires that only the specified
refrigerant be used in your machine. Alternative
refrigerants may cause damage to the cooling
system and/or prevent the machine from
operating at optimal performance. If you require
an alternative refrigerant, please call Spaceman
USA Technical Support for a list of compatible
alternatives for your compressor.
Main compressor:
1x 8000 BTU, R404A
Machine placement requirements
Place machine on a flat, level, and
solid surface fitted to its
dimensions.
Ensure a minimum 6-inch clearance
on all sides, front, and back.
Completely clear area of dust,
grease, and airborne particles.
Place away from hot equipment
such as stoves, frying baskets,
ovens, etc.
CAUTION: The machine must be placed on a level surface away from walls and other objects.
Failure to comply will damage the machine and refrigeration components and will void all warranties.
CAUTION: The machine is designed to operate in normal ambient temperatures of 60 to 75
o
F.
Operating in higher ambient temperatures will result in degraded performance.
5