Sanitiza-
IMPORTANT: After sanitizing the machine, DO NOT rinse or touch areas that have been sanitized.
Product must be added immediately. If new product will not be added immediately, rinse machine
with clean water and loosen door hand-screws to allow cylinder to air-dry. Sanitize machine before
using again.
1. Verify assembly is complete and
machine power is OFF
2. Verify the draw valve is in the CLOSED
position (LEFT)
3. Mix a minimum of 2 gallons of food-
grade sanitizer in a bucket or container
4. Pour a minimum of 2 gallons of food-
grade sanitizer solution into the hopper
5. Turn power switch to WASH
6. Allow solution to agitate for 5 to 10
minutes; NEVER leave machine on WASH
for more than 10 minutes
7. While agitating, gently use a clean brush
to scrub and distribute sanitizer solution
along hopper walls and hopper agitator
(if present)
8. Place a bucket or container below the
draw valve
9. OPEN the draw valve (RIGHT) and drain
solution from the machine
10. Turn power switch to OFF
1
8
2
3
7
9
10
3
4
5
6
13
Sanitization
CAUTION: Always use food-grade, no-rinse sanitizer to sanitize. If warm water is required to
dissolve sanitizer, allow the solution time to cool before adding to machine.