Spaceman SM-6690H Machine Manual Download Page 16

www.spacemanusa.com 

Phone: (720) 328-1020 

Email: [email protected] 

Freeze product 

1.  Verify cylinder is full of mixed product 

2.  Turn power switch to FREEZE and verify 

STANDBY mode is off (see below)  

3.  The motor will begin to agitate the 

product, and the cooling system will 
begin to freeze the product 

4.  Freezing product takes approximately 10 

minutes; product is at the adjusted 
viscosity when the flat sensor arm is 
switched to the RIGHT 

5.  When the product reaches the desired 

viscosity, it is ready to dispense 

Dispense product 

1.  OPEN draw handle (RIGHT) until the desired 

amount is dispensed 

2.  CLOSE the draw handle (LEFT) when finished 

dispensing 

CLOSED 

OPEN 

15 

Frozen Product Operation 

IMPORTANT: When the machine will NOT be 
utilized for several hours, place it in STANDBY 
mode to conserve electricity and reduce 

product loss.  

In STANDBY, product remains below 41

o

F in 

both the cylinder and hopper, but will NOT be 
frozen. 

To exit STANDBY mode: 

 

Press STANDBY indicator light on front of 
machine, and green light will de-illuminate. 

 

Allow 5 to 10 minutes for machine to begin 
freezing again. 

To enter STANDBY mode: 

 

Press STANDBY indicator light on front of 
machine. 

 

Light illuminates green when machine is in 
STANDBY mode. 

NOTE: If machine doesn’t turn on, turn power switch OFF, wait 
30 minutes, and repeat steps 1 to 4.  If problem persists, contact 
service team. 

CAUTION: If machine makes any abnormal noise during reset, 
immediately turn power switch OFF and contact service team. 

IMPORTANT: Machine shuts 
down automatically if 
cylinder experiences freeze-
up 
(usually because the 
viscosity is set too high for 
the selected product to 
prevent motor damage. 

Use the green reset button 
on the machine’s back panel 
to return the machine to 
normal operation. 

Proper Machine Reset 
1.  Turn power switch to OFF 
2.  Firmly press green reset button 
3.  Wait 15 to 20 minutes. 
4.  Turn power switch to WASH 
5.  Observe machine performance 

Machine power reset 

Standby mode 

Summary of Contents for SM-6690H

Page 1: ...Commerce Street Suite B Broomfield CO 80020 Customer Service Sunday Saturday 8 AM 5 PM Mountain Toll Free 1 888 610 5520 Local 1 720 328 1020 service spacemanusa com Sales and Product Information Mond...

Page 2: ...his manual may be subject to change Please check online or contact Spaceman USA Technical Support at 720 328 1020 for continued updates training and detailed information about your Spaceman machine We...

Page 3: ...tine maintenance 7 Clean 8 Drain frozen product 8 Disassemble parts 9 Wash parts 10 Assemble parts 11 Sanitize 13 Manage frozen product 14 Add product to machine 14 Freeze product 15 Dispense product...

Page 4: ...ect machine parts and accessories 2 Place machine in appropriate food preparation area Comply with all installation requirements Read and understand ALL safety and standard operating procedures 3 4 5...

Page 5: ...2 Ice Buster 1 Draw Valve Pin 1 Draw Handle 1 Beater 1 Scraper Blades 2 Scraper Blade Clips 2 Beater Guide 1 Door Hand Screws 4 Torque Assembly 1 with O Ring 1 Drive Shaft 1 Drive Shaft Gasket 1 Brus...

Page 6: ...refrigerants may cause damage to the cooling system and or prevent the machine from operating at optimal performance If you require an alternative refrigerant please call Spaceman USA Technical Suppo...

Page 7: ...ng to the Installation Requirements Page 5 Unpalletizing requires lifting Two or more personnel should remove the machine from its packaging and place it in its final operating location Failure to do...

Page 8: ...y The machine comes equipped with a brush kit specifically designed to efficiently and properly clean the machine IMPORTANT Cleaning and sanitizing schedules are governed by state or local regulatory...

Page 9: ...es and bottom of the hopper be VERY careful not to damage the low mix sensor in the hopper 11 Use the small brush kit to clean inside the feed tube at the bottom of the hopper 12 Place a bucket or oth...

Page 10: ...ed to OFF 2 Remove the torque arm first pulling up out of the torque assembly and then down out of the flat sensor arm DO NOT LIFT UP ON CURVED SENSOR ARM 3 Remove dispensing door hand screws 4 4 Remo...

Page 11: ...ently clean and wipe down the outside of the machine 5 Carefully and thoroughly wash all parts removed from the machine using supplied brushes sponges and clean towels when cleaning the dispensing doo...

Page 12: ...ill no longer turn 360 1 3b 2c 3a 4a 3c 4c 4d 11 2a 2b 4b Cleaning 4 Assemble 1 Verify machine power switch is in the OFF position 3 Install beater assembly a Install scraper blade clips 2 onto scrape...

Page 13: ...n door coating with Spaceman lubricant i Place beater guide onto dispensing door with flange flush with the back of the door j Align door assembly with torque assembly and mounting bolts carefully lif...

Page 14: ...sanitizer in a bucket or container 4 Pour a minimum of 2 gallons of food grade sanitizer solution into the hopper 5 Turn power switch to WASH 6 Allow solution to agitate for 5 to 10 minutes NEVER leav...

Page 15: ...11 Replace hopper lid 1 Verify machine has been recently sanitized within 1 hour if machine has not been recently sanitized verify door hand screws are tight and perform sanitizing steps Page 13 2 Tur...

Page 16: ...n both the cylinder and hopper but will NOT be frozen To exit STANDBY mode Press STANDBY indicator light on front of machine and green light will de illuminate Allow 5 to 10 minutes for machine to beg...

Page 17: ...justment screw Make small adjustments each time and allow at least 10 to 15 minutes between adjustments to evaluate product firmness Increase viscosity more firm Turn viscosity adjustment screw clockw...

Page 18: ...talled scraper blades 3 Viscosity adjustment is set incorrectly 4 Beater is rotating counter clockwise Remedy 1 Follow manufacturer instructions for mixing product ensure correct mix ratios 2 Inspect...

Page 19: ...15 8 Contact Spaceman USA Technical Support Probable Cause 1 Improper or inadequate lubrication of drive shaft gasket 2 Damaged missing or improperly installed drive shaft gasket Remedy 1 Use suffici...

Page 20: ...www spacemanusa com Phone 720 328 1020 Email service spacemanusa com www spacemanusa com Phone 720 328 1020 Email service spacemanusa com Machine Specifications 19...

Page 21: ...cator 6 3 1 03 04 015 Standby Switch 7 3 1 03 03 002 Power Switch 8 2 3 4 17 005 Panel Front L Item Part Description 9 2 1 1 10 0004 Beater 10 3 4 04 01 002 Drip Tray 11 3 6 39 004 Drip Tray Mount 12...

Page 22: ...ive Shaft Gasket 18 2 1 1 10 0004 Beater 19 2 3 6 03 007 Torque Arm Dispensing Door and Beater Item Part Description 1 2 1 4 04 018 Draw Lever 2 3 6 22 026 Visc Screw M5x45 3 2 1 4 04 012 Viscosity Ho...

Page 23: ...Capacitor Start 18 3 2 03 04 002 Fan Motor Main 19 3 2 03 04 002 1 Fan Cover 20 3 3 01 07 003 Motor 600W 21 3 3 04 01 005 Bushing 1008 22 3 3 04 02 012 Pulley 63x1 1008 23 3 3 03 01 002 Belt XPA950 2...

Page 24: ...tor KM 3 1 01 01 010 Contactor JR 3 1 01 02 010 Thermal Relay T 3 1 01 04 007 Transformer S1 2 3 2 04 06 004 Pressure Switch Item Part Description S10 3 1 01 07 002 Thermostat C S11 3 1 03 04 015 Stan...