16. Mode 6 Easy Guide                                                                                           

 

 

Enter the programming mode 

Press    *    +    1      2      3      4      5      6    +    #   
(all new units are preprogrammed with the master code 123456) 

The LED will flash green rapidly to show that the unit is in the programming mode. The 

unit will time out and return to the reading mode in 30 seconds if no key is pressed. 

 

 

Add one Transponder (Card / Key Tag) to the system 

Step1: Press    *    and master code fallow an    #   
Step2: Enter    1      1      *      1      5      0      3      1      *     

Starting Card Code 

  1      5      0      3      1      #   

        Ending Card Code 

A green light and beep means that the transponder was accepted. 

Step3: Press    *      #   

 

 

Add a series of Transponders (Card / Key Tag) to the system 

Step1: Press    *    and master code fallow an    #   
Step2: Enter    1      1      *      1      5      0      3      1      *     

Starting Card Code 

  1      5      0      3      8      #   

Ending Card Code 

Set sequential transponder once and make a careful record. A green light and 

beep means that the transponder was accepted. 

Step3: Press    *      #   

 
 
 
 
 
 
 
 
 
 
 
 

 

33

Add the common Code to the system 

Step1: Press    *    and master code fallow an    #   
Step2: Enter    1      5      *      4      3      2      1      #   

                                                  Common Code 

All users can access the door by only entering common code (Default value: 

4321) on the unit. 

OR      Enter    1      5      *      0      0      0      0      #   

                                              Common Code 

This function is disable. All users cannot access the door by only entering common 

code. 

OR      Enter    1      7      *      1      2      3      4      #   

                                          Common Code 

All users can access the door by flashing card and entering common code 

(Default value: 1234) on the unit. 

OR      Enter    1      7      *      0      0      0      0      #   

User can access the door by flashing card on the unit. 

Step3: Press    *      #   

 

 

Set system clock times 

Step1: Press    *    and master code fallow an    #   

(all new units are preprogrammed with the master code 123456) 

Step2: Enter    2      5      *      Y      Y      M      M      D      D      H      H      m   

    m      S      S      #   

YY: Year      MM: Month      DD: Date      HH: Hour    mm: Minute      SS: Second 

(Ex. 000125 = 25

th

 January, 2000)     

(Ex. 235901 = 23:59:01 PM) 

Step3: Press    *      #   

 

 

Other operation is same as AR-721H4 Easy Guide, for example, exit the 

programming mode, change master code, door relay release time, delete one 

  or many transponder and so on.   

 

 

34

17. Mode 7 Easy Guide                                                                                           

 

To exit the programming mode 

Press    *      #    -- exit the programming mode and return to the reading mode. 

 

 

Set a user number arrive one floor 

Step1: Press    *    and master code fallow an    #   
Step2: Enter    2      7      *      0      0      0      0      1      *     

User Number 

  3      1      #   

Access 31

st

 floor 

A green light and beep means that the setting was accepted. 

Step3: Press    *      #   

 

 

Set a user number arrive many floor 

Step1: Press    *    and master code fallow an    #   
Step2: Enter    2      1      *      0      0      1      *     

User Number 

  0      *      1      1      0      0      0      0      1      1      #   

Group                Access 8

th

, 7

th

, 2

nd

, and 1

st

 floors 

 

 

 

 

 

 

 

 

 

 

 

 

A green light and beep means that the setting was accepted. 

Step3: Press    *      #   

Group 

Floor address 

8      7        6      5      4      3      2        1 

16    15    14    13    12    11    10      9 

24    23    22    21    20    19    18    17 

32    31    30    29    28    27    26    25 

 

 

 

 

35

Set a AR-721R32 node address (AR-401RO16 don’t need to set this command.   

It is set by DIP switch on the device) 

Step1: Press    *    and master code fallow an    #   
Step2: Enter    2      4      *      0      0      1      #   

                      AR-721R32 node address 

A green light and beep means that the setting was accepted. 

Step3: Press    *      #   

 

 

Set the Relay time for push button and present card input of an elevator   

controller 

Step1: Press    *    and master code fallow an    #   
Step2: Enter    2      3      *      0      0      1      *     

AR-721R32 node address 

  0      3      0      *      0      0      5      #   

Pushbutton input          Present card input 

A green light and beep means that the setting was accepted. 

Step3: Press    *      #   

 

Note:  AR-401RO16  has  no  push  button  input  function,  but  you  still  enter  push 

button input second in order to complete this command. Otherwise, this command 

will be failed). 

 

Other operation is same as AR-721H4 Easy Guide, for example, enter the 

programming mode, change master code, door relay release time, add / delete / 

enable one or many transponder and so on.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for AR-721HV3

Page 1: ...d 2 Features Calendar Time system supporting Providing proximity card flash edit mode for easy quick setting Two Sets of Auto Open Zone Function Built in opened door relay alarm relay and request to e...

Page 2: ...ate power supply for the AR 721H and strike 11 Run the following cables to the AR 721H location Conduit is recommended to reduce the effects of EMI RFI and for physical protection of the wires 6 We su...

Page 3: ...ver and setting 4 sets of Force code on PC Anyone of these 4 sets is workable User could press related code to turn on off its connected equipment diagram as below PC boad of Controller AR 716EV2 AR 7...

Page 4: ...in Blue Wiegand DAT 1 Input Wiegand 2 Thin Green Wiegand DAT 0 Input Beeper 3 Pink Beeper Output 5V 100mA Low 4 Brown LED Green Output 5V 20mA Max LED 5 Yellow LED Red Output 5V 20mA Max Table 3 Conne...

Page 5: ...rm system AR 721H Standalone Controller The installation of 721H Megnetic Door Contacts CN4 721H 7AC2 Magnetic Door Contacts NC Magnetic Door Contacts COM 12VDC 2A Power Supply RELAY Orange Door Senso...

Page 6: ...connecting disance between the 801cm and your pc can not be more than 2m CH1 Green Blue Blue Green CN1 SOYAL CN3 Blue Green 7AC2 CN2 CN4 721H RELAY SOYAL CN3 7AC2 CN2 CN4 721H Black Red CN2 CN3 RELAY...

Page 7: ...pping charges and to use the original shipping container or equivalent Customers shall seek assistance from the distributor who sold you product s Repaired or replaced product s are warranted for nine...

Page 8: ...beep means that the range of transponders user codes were deleted Step3 Press 30 Delete all Transponders Step1 Press and master code fallow an Step2 Enter 2 9 2 9 The LED flash red during 10 seconds...

Page 9: ...25 25th January 2000 Ex 235901 23 59 01 PM Step3 Press Other operation is same as AR 721H4 Easy Guide for example exit the programming mode change master code door relay release time delete one or man...

Page 10: ...llow White Purple Green Bule Black Red Output Selection AR 721H do anti pass back with 2 pcs of AR 661U Black Red Black Bule Green Purple White Yellow Red 38 When the distance between 2 pcs 661U is le...

Page 11: ...721HV3 series in this function Press 2 8 0 6 4 Open two doors This function is good for using together with auxiliary reader AR 721 HV3 and auxiliary reader open different door Note that this functio...

Reviews: