background image

ELECTRIC SYSTEM - 

SCHEMA 

ELECTRIQUE 

VALVE

TERMOST.

BLUE

MOTORFAN

COMPRESSOR

ELECTRO

BLACK

ELECTRONIC CARD

2 F1

3 ACL

5 LE2

6 LE1

4 LE3

1 ACN

M1(ev)

M2(fan)

1

6

3

7

RED

4

BLUE

COMPRESSOR

CAPACITOR

BROWN

BLUE

PURPLE

Float

F4

AC-N

F6

AC

-L

L out B2

L out B1

L out A1

F7

F5

F3 F2

F1

C

1 2

RED

GREY

FLOAT

Input

HOUR

COUNTER

8

1

6

5

4

3

2

COM NC NO

RED

GREY

1

6

5

4

3

2

BLUE

BLACK

2

9

10

11

13

17

18

19

5

HUMIDISTAT

TANK FULL

FLOAT PCB

FLOAT SENSOR

12

FAN SPEED SWITCH

RESISTOR

20

PUMP

SOCKET

FAN

CAPACITOR

PUMP

PLUG

PUMP

CONNECTION 

REMOTE 

DEHUMIDISTAT

21

3

2

RED

PURPLE

BLUE

BLACK

BLUE

BLUE

BROWN

BROWN

RED

ORANGE

BLUE

BLACK

120V

BLACK

BROWN

15

22

VOLTAGE 

SWITCH

TRAFO

14

POWER

CORD

BROWN

240V

0V

BLUE

BLACK

WHITE

1

6

5

4

3

2

BRIDGE

PLUG

16

VALVE

TERMOST.

BLUE

MOTORFAN

COMPRESSOR

ELECTRO

BLACK

ELECTRONIC CARD

2 F1

3 ACL

5 LE2

6 LE1

4 LE3

1 ACN

M1(ev)

M2(fan)

1

6

3

7

RED

4

BLUE

COMPRESSOR

CAPACITOR

BROWN

BLUE

PURPLE

Float

F4

AC-N

F6

AC

-L

out B2

out B1

out A1

F7

F5

F3 F2

F1

C

1 2

RED

GREY

FLOAT

Input

HOUR

COUNTER

8

1

6

5

4

3

2

COM NC NO

RED

GREY

1

6

5

4

3

2

BLUE

BLACK

2

9

10

11

13

17

18

19

5

HUMIDISTAT

TANK FULL

FLOAT PCB

FLOAT SENSOR

12

FAN SPEED SWITCH

RESISTOR

20

PUMP

SOCKET

FAN

CAPACITOR

PUMP

PLUG

PUMP

CONNECTION 

REMOTE 

DEHUMIDISTAT

21

3

2

14

POWER

CORD

RED

PURPLE

BLUE

BLACK

BLUE

BLUE

BLACK

BROWN

BROWN

RED

ORANGE

BLUE

BLACK

WHITE

1

6

5

4

3

2

BRIDGE

PLUG

16

DR

 56 

L

 

Summary of Contents for DANTHERM DR 56 L

Page 1: ...NOTICE TECHNIQUE D shumidificateur mobile DR 56 L...

Page 2: ...ATA DONN ES TECHNIQUES MODELE DR 56 L 38 99 3 35 C 500 m h 56 l 24 h R410A 440 g GWP 1975 220 240 V 50 Hz 3 9 A 780 W dB A 53 dB 10 5 l 45 kg PS 41 5 33 Bar TS 65 55 C LRA 21 A 30 C UR 80 30 80 27 C U...

Page 3: ...1 2 3 4 0000 XXXX 1 7 2 6 3 4 1 2 3 4 5 9 6 7 8 1 2 3 4 6 5 5 PICTURES FIGURES...

Page 4: ...PICTURES FIGURES 5 6 7 8 9 10 11 12 110V 240V 1 1 0 V 1 1 0 V 2 4 0 V 2 4 0 V 2 4 0 V...

Page 5: ...PICTURES FIGURES 13 14 15 16 17 18 5 4 6 4 2 3 1 3...

Page 6: ...FIER This appliance is equipped with a handle This component is contained within the packaging of the dehumidifier To install the handle follow the below steps Fig 1 2 3 1 Remove the screw that secure...

Page 7: ...rect dehumidifier operation completely rotate the knob of the humidistat on the control panel 1 Fig 4 to CONT and set the desired humidity on the remote humidistat 9 IF THE DEHUMIDIFIER DOES NOT START...

Page 8: ...d crits ci dessous 3 ASSEMBLAGE DU D SHUMIDIFICATEUR Ce mod le est dot d une poign e Ce composant est contenu l int rieur de l emballage du d shumidificateur Pour installer la poign e suivre la proc...

Page 9: ...ce 5 Fig 4 retirer le bouchon connect au d shumidificateur et connecter l hygrostat distance en option Fig 11 Pour un bon fonctionnement du d shumidificateur tournez enti rement le bouton de l hygrost...

Page 10: ...BROWN BLUE PURPLE Float F4 AC N F6 AC L L out B2 L out B1 L out A1 F7 F5 F3 F2 F1 C 1 2 RED GREY FLOAT Input HOUR COUNTER 8 1 6 5 4 3 2 COM NC NO RED GREY 1 6 5 4 3 2 BLUE BLACK 2 9 10 11 13 17 18 19...

Page 11: ...prevent possible negative consequences for health the environment and mankind fr SE D BARRASSER DE VOTRE PRODUIT USAG Ce produit a t con u et fabriqu avec des mat riaux et des composants de haute qua...

Reviews: