South Bend Tools
For Machines Mfd. Since 12/20
Model SB1108/SB1109
-31-
O P E R A T I O N
Digital Readout
Calibrating Digital Readout
1.
Raise table all the way up.
2.
Press mm/in button until 'in' is displayed.
3.
Press ABS/INC button until ABS is
displayed. (This should already be displayed
by default after the batteries are replaced.)
4.
Press and hold ON/OFF (CAL) button until
ABS begins to flash (2–3 seconds).
5.
Press + (mm/in) or – (ABS/INC) buttons to
adjust readout until it displays
1
⁄
4
".
6.
Press ON/OFF button to return to normal
operating mode.
The digital readout is powered by 2 AAA
batteries. The readout will display a battery
icon when the battery level is low and needs
replacing. Each time the batteries are replaced,
the digital readout will need to be calibrated.
To calibrate digital readout:
Figure 31. Digital readout.
The digital readout has two modes of use,
Absolute (ABS) and Incremental (INC).
When used in ABS mode, the readout displays
the distance between the table and the edge
of the cutterhead insert at bottom-dead-center
(BDC) to show workpiece thickness.
When INC mode is used, the readout displays the
distance between the current position of the table
and the position of the table where incremental
mode was set at 0 to show how much material
was removed from the workpiece.
To enter INC mode, press ABS/INC until INC is
displayed. Each time the unit is placed in INC
mode, the incremental value is reset to 0.
mm/in (+)
ABS/INC (–)
ON/OFF (CAL)