South Bend Tools
For Machines Mfd. Since 10/20
Model SB1100 & SB1101
-3-
I N T R O D U C T I O N
Description of Controls
& Components
C
D
E
F
G
Figure 1. SB1100 & SB1101 components.
Figure 2. SB1100 & SB1101 remote control.
Refer to Figures 1-2 and the following
descriptions to become familiar with the basic
controls and components used to operate this
machine.
A. Switch Box:
Controls motor operation with a
thermally protected magnetic switch. Houses
an RF receiver for remote control operation.
B. Start Button:
Turns machine ON.
C. Emergency Stop Button:
Turns machine
OFF and prevents it from starting. Turn
button clockwise to reset.
D. Filter Brush Motor:
Turns ON for
approximately 90 seconds after main motor
is turned OFF. Knocks dust cake off filter
pleats, cleaning filter and maintaining air
flow. Filter brush motor run time can be
changed at timer inside switch box (refer to
Wiring on Page 44).
E. Pressure Gauge:
Displays vacuum pressure,
indicating when filter and collection bags
need to be cleaned or replaced. Clean filter
when operating pressure drops below
200mmAq. If operating pressure reaches
150mmAq and cleaning does not improve
performance, replace the filter.
F. Collection Bag:
Collects fine dust particles
from filter.
G. Remote Control:
Green button turns motor
ON. Red button turns motor OFF. Requires
a 12V, type A27 battery.
Note: The remote control operates on radio
frequency and has a 75-ft. range. It does not
need to be aimed at the switch box to operate.
A
B