-30-
For Machines Mfd. Since 10/20
South Bend Tools
Model SB1100 & SB1101
S Y S T E M D E S I G N
Figure 52. Example materials list.
Example Materials List
After the system is designed, create a materials
list of all the items you will need to build your
dust collection system. This will make it easy
when it comes time to purchase the materials.
Below is an example of some items that might be
needed.
Description
Model
Quantity
6" Rigid Duct at 20'
G7364
4
4" Rigid Duct at 10'
G6162
2
4" Flex Hose at 5'
H7215
6
6" 45° Y-Branch
G7353
6
4" 45° Elbow
G6167
6
Figure 50. SB1100 performance data.
1103
SB1100 Performance Curve
CFM
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0 11.0 12.0
STATIC PRESSURE (Inch/H2O)
The air flow test probe is located 1.5x duct diameter upstream
from the air inlet. Test pipe length is a minimum of 10x duct
diameter.
2 HP DUST COLLECTOR PERFORMANCE RESULTS
Max CFM Max SP
HP
Volts
Inlet
Impeller
1132
11.95
2 HP
220V
6"
12"
Restrictor Plate Dia. 6"
5"
4"
3"
2"
1"
0"
Static Pressure
(Inch/H2O)
3.5
4.8
7.9 10.7 11.4 11.5 12.0
CFM
1103 1013 759 475 187 200 212
Figure 51. SB1101 performance data.
1429
SB1101 Performance Curve
CFM
2000
1800
1600
1400
1200
1000
800
600
400
200
0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0 11.0 12.0
STATIC PRESSURE (Inch/H2O)
The air flow test probe is located 1.5x duct diameter upstream
from the air inlet. Test pipe length is a minimum of 10x duct
diameter.
3 HP DUST COLLECTOR PERFORMANCE RESULTS
Max CFM Max SP
HP
Volts
Inlet
Impeller
1429
12.03
3 HP
240V
7"
12
3
⁄
4
"
Restrictor
Plate Dia.
7"
6"
5"
4"
3"
2"
1"
0"
Static
Pressure
(Inch/H2O)
3.2
4.1
6.5
9.4
11.3 11.7 11.9 12.0
CFM
1429 1328 1115 667 319 305 491 360