8
ENGLISH
ZEUS II series User manual
5. REAR PANEL - A-300, A-600, A-900
WARNING: TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK, REPLACE FUSE
ONLY WITH SAME TYPE
F15A-250V.
MADE IN P.R.C.
S/N:
ZEUS SERIES
POWER AMPLIFIERS
230V - 50/60Hz
WARNING! ONLY USE THE
POWER CABLE SUPPLIED
WITH THIS PRODUCT
CH-A
CH-A
BRIDGE
CH-B
CH-B
OUTPUTS
INPUTS
LIMITER
MODE
GROUNDLIFT
ON
OFF
BRIDGE
STEREO
LIFT
GND
Input Impedence:
20K Balanced / 10K Unbalanced
GND
BRIDGE
A
B
MONO
PINOUT
CH-B
CH-A
BRIDGE
1
2
7
3
5
4
6
8
1)^AC POWER CONNECTOR
Plug the power cord into an AC socket properly configured for your particular model.
Note: If you happen to lose the AC line-cord, always use a three-pin plug
with a ground pin. The wire correspondence is as follow:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
Always connect the earth! Pay attention to your safety!
Before taking into operation for the first time, the installation has to be approved by an
expert.
2)^OUTPUT CONNECTORS
Each channel has one Speakon® and one binding post outputs for connecting to the
loudspeakers.
3)^INPUT CONNECTORS
Each channel has one balanced XLR and one balanced jack TRS inputs.
4)^GROUND LIFT Switch
The ground lift switch eliminates unwanted hum and buzz by interrupting the ground
loops between equipment, preventing current flow along the cable shield between two
devices.
5)^COOLING FAN
The device is equipped with an Intelligent Cooling System so that there is a forced
airflow from the front to the back for cooling the device when needed.