background image

17

ENGLISH

MHL-200 User’s manual

CH10

Gobo Wheel

168-173

Gobo4 shakes (slow-fast)

174-179

Gobo3 shakes (slow-fast)

180-185

Gobo2 shakes (slow-fast)

186-191

Gobo1 shakes (slow-fast)

192-223

Gobo wheel clockwise rotation (fast-slow)

224-225

Gobo wheel anticlockwise rotation (slow-

fast)

CH11

Dark Movement

0-85

Position

86-171

Dark Moment

172-255

Position

CH12

Function

0-255

Inside Program

CH13

Focus 

0-255

Focus  0% - 100%

CH14

Prism insertion

0-127

Prism excluded

128-255

Prism inserted

CH15

Prism Rotation

0-2

Position

3-127

Rotating anticlockwise from fast to slow

128

Stop

129-255

Rotating clockwise from slow to fast

CH16

Lamp Control / 

Rest

0-127

Unused Range

128-200

Lamp off (staying 5 seconds)

201-254

Lamp on (staying 5 seconds)

255

Rest (staying 5 seconds)

5. ADDRESSING

The control board on the front side of the base allows you to assign the DMX 

fixture the address, which is defined as the first channel. For example, if you 

set the address to channel 5, this lighting will use the channel 5 to 16 for con-

trol.
Please make sure that you do not have any overlapping channels in order to 

control each lighting correctly and independently from any other fixture on the 

DMX data link.

5.1. ADDRESSING SETTING

1.  Turn on the moving head. Wait till finishing the reset (RST flashes on the 

display).

Summary of Contents for MHL-200

Page 1: ...USER S MANUAL Please read this manual carefully and proper take care of this manual MHL 200 200W Beam Moving Head with philips 5R lamp ...

Page 2: ...is item and if you want to collaborate we are looking for a feedback from you about the operation of the product and possible improvements to introduce in the next future Go to our website www soundsationmusic com and send an e mail with your opinion this will help us to build instruments ever closer to customer s real requirements One last thing read this manual before using the instrument an inc...

Page 3: ... 1 Lamp Fitting Replacing 10 3 2 Brightness adjustment 10 3 3 Rigging and Hook 10 4 CONNECTIONS 12 4 1 Mains Connections 12 4 2 DMX 512 Connection 13 4 3 Building a Serial DMX Chain 13 4 4 DMX Channels 14 5 ADDRESSING 17 5 1 Addressing setting 17 5 2 Controlling 18 6 TECHNICAL SPECIFICATIONS 18 7 MAINTENANCE AND CLEANING 19 7 1 Replacing The Fuse 20 8 WARRANTY AND SERVICE 22 9 WARNING 23 ...

Page 4: ... terminal Denotes the apparatus is turned on Denotes the apparatus is turned off WARNING Describes precautions that should be observed to prevent the danger of injury or death to the operator CAUTION Describes precautions that should be observed to prevent dan ger of the apparatus 1 2 IMPORTANT SAFETY INSTRUCTIONS f f Read these instructions f f Keep these instructions f f Heed all warning f f Fol...

Page 5: ...ed Object and Liquid Entry Objects do not fall into and liquids are not spilled into the inside of the appara tus for safety Installation Always secure fixture using a safety chain and carrying handles Never carry the fixture by its cord Power Cord and Plug This device falls under protection class 1 The power plug must only be plug ged into a protection class 1 outlet Handle the power cord all con...

Page 6: ...ocess and does not necessarily mean that the device is defective DMX connection When use DMX controller please make sure that there is no interference sources e g intercom high frequency radio waves and radiation source Cleaning Clean only with a dry cloth Do not use any solvents such as benzol or alcohol Servicing In case of failure or misfunction occurred stop using the unit immediately Never tr...

Page 7: ...e fixture after having checked that the housing is firmly closed and all screws are tightly fastened The lamp must never be ignited if the objective lens or any housing cover is open as discharge lamps may explode and emit a high ultraviolet which may cause burn The maximum ambient temperature must never be exceeded CAUTION The lens has to be replaced when it is obviously dam aged so that its func...

Page 8: ... digit LED display f f Silent fans cooling f f 16 DMX channels f f Pan movement rang 530 Tilt movement rang 280 f f High luminous efficiency parabolic mirror and double condenser system f f Mechanical multi step focus f f DMX controllable Focus is f f Pre programmed changeable grating pulse effect f f All lenses are anti reflection coated f f 9 high quality stepper motors for smooth movement f f S...

Page 9: ...ound the unit for proper ventilation and prevent overheating do not place the unit on top of hot devices such as radiators or power amplifiers The fixture is connected to mains through the supplied cable The product meets the required safety standards Blown fuses must be replaced with fuses of the same type and specification Make sure that all units must be properly grounded For your safe ty you s...

Page 10: ...ADJUSTMENT The brightness of the lighting has been aligned at the factory Due to the diffe rence between lamps fine adjusted may improve light performance Strike the lighting open the grating and the diaphragm adjust the brightness to 100 and then focus the light on a flat surface e g on a wall Through using three A B C adjusting screws you can make the light focus on the hot spot the brightest of...

Page 11: ...measu re and the machine s technical installation once a years WARNING The fixture should be installed outside areas where per sons may walk by or be seated IMPORTANT Overhead rigging requires extensive experience inclu ding but not limited to calculating working load limits installation material being used and periodic safety inspection of all installa tion material and the projector If you lack ...

Page 12: ...ibilities to fix the base of the lighting Use the rigging clamp to merge M10 or M12 screw please check the base For overhead use always install a safety rope that can hold at least 10 times the weight of the fixture 4 CONNECTIONS 4 1 MAINS CONNECTIONS Connect the device to the mains with the power plug The wire corresponden ce is as follow Cable Pin Intermational Brown Live L Blue Neutral N Yellow...

Page 13: ...wish to connect DMX controllers with other XLR output you need to use adapter cables 4 3 BUILDING A SERIAL DMX CHAIN Connect the DMX output of the first fixture in the DMX chain with the DMX in put of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected A word on termination DMX is a resilient communication protocol however errors still occ...

Page 14: ...nel Function Data Function Description CH1 Pan 0 255 Rotate 540 degree CH2 Tilt 0 255 Rotate 270 degree CH3 Pan Fine 0 255 Pan fine CH4 Tilt Fine 0 255 Tilt fine CH5 Pan Tilt Speed 0 255 Control Pan Tilt speed CH6 Frost 0 127 Frost excluded 128 255 Frost inserted CH7 Strobe 0 3 Strobe from slow to fast 4 Slow strobe 103 Fast strobe 104 107 Open 108 Slow pulsation 207 Fast pulsation 208 212 Open 21...

Page 15: ...ld white 105 110 Cold white White 111 116 Cold white CTB 117 122 CTB Pink 123 128 Pink Light blue 129 134 Light blue Amber 135 140 Amber Yellow green 141 146 Yellow green CTO 147 152 CTO UV 153 158 UV Magenta 159 164 Magenta Orange 165 170 Orange Green 171 176 Green Blue 177 182 Blue Yellow 183 188 Yellow Red 189 191 Red White 192 223 Color wheel clockwise rotation fast slow 224 225 Color wheel an...

Page 16: ...obo15 80 84 Gobo16 85 89 Gobo17 90 95 Gobo17 shakes slow fast 96 101 Gobo16 shakes slow fast 102 107 Gobo15 shakes slow fast 108 113 Gobo14 shakes slow fast 114 119 Gobo13 shakes slow fast 120 125 Gobo12 shakes slow fast 126 131 Gobo11 shakes slow fast 132 137 Gobo10 shakes slow fast 138 143 Gobo9 shakes slow fast 144 149 Gobo8 shakes slow fast 150 155 Gobo7 shakes slow fast 156 161 Gobo6 shakes s...

Page 17: ...rom fast to slow 128 Stop 129 255 Rotating clockwise from slow to fast CH16 Lamp Control Rest 0 127 Unused Range 128 200 Lamp off staying 5 seconds 201 254 Lamp on staying 5 seconds 255 Rest staying 5 seconds 5 ADDRESSING The control board on the front side of the base allows you to assign the DMX fixture the address which is defined as the first channel For example if you set the address to chann...

Page 18: ...not connected with the input of the moving head light The controller is switched off or defective if the cable or con nector is defective or the signal wires are swap in the input connector Note It s necessary to insert the XLR termination plug with 120 Ohm in the link in order to ensure proper transmission on the DMX data link 6 TECHNICAL SPECIFICATIONS Power Supply 230 240V AC 50Hz Fuse T5A 250V...

Page 19: ...emperature Maximum ambient temperature 40 degree Maximum housing temperature 80 degree Dimensions and Weight Length of base including handles 520mm Width 520mm Height head horizontal 700mm Net weight 28kg Shipping weight 30kg 7 MAINTENANCE AND CLEANING The operator must make sure that correlative safety equipment and an expert inspects machine s technical installations after every four years in th...

Page 20: ...quire weekly cleaning as smoke fluid tends to building up residues reducing the light output very quickly The cooling fans should be cleaned monthly The gobos may be cleaned with a soft brash The interior of the fixture should be cleaned at least annually using a vacuum cleaner or an air jet The dichroic color filters the gobo wheel and the internal lenses should be cleaned monthly To ensure a pro...

Page 21: ... holder f f STEP 4 Replace the fuse holder Should you need any spare parts please use genuine parts If the power supply cable of this device becomes damaged it has to be repla ced by authorized dealers only in order to avoid hazards Should you have further questions please contact your dealer We hope you will enjoy your lighting We can assure you that you will enjoy this device for years if you fo...

Page 22: ...at SOUNDSATION s discretion either by repair or by exchanging individual parts or the entire appliance Any defective parts removed from a product during the course of a warranty claim shall become the property of SOUNDSATION While under warranty period defective products may be returned to your local SOUNDSATION dealer together with original proof of purchase To avoid any damages in transit please...

Page 23: ... Improper handling of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous substanc es that are generally associated with EEE At the same time your cooperation in the correct disposal of this product will contribute to the effective usage of natural resources For more information about where you can drop off your waste equipment ...

Page 24: ...www soundsa tionmusic com Ver 1 0 July 2015 ...

Reviews: