V1.22
Owners Manual SP20-Linex™
- 12 -
Project info page
figure 4.1 Project info page screenshot
When starting a new project, the first page to look at is the
project info
page, here the venue
specific parameters can be entered. SPArC™ uses these in several calculations.
Main interface page
figure 4.2 Main interface page screenshot
The second page in SPArC™ is the main interface. Here a coverage side view is given together
with an SPL prediction for the audience (right scale-axis). Furthermore, the manual adjustment
setting gives full control to optimize vertical array coverage. In addition several automatic
configuration algorithms can be used.
Auto and manual configuration
When the
auto
configuration is turned “on” the graph at the “Main interface” page corresponds
with calculated angle settings. SPArC™ uses the data on the “Project info” page to calculate a
near to optimum array shape. It is recommended by SP to use an array shape as close as
possible to these settings. The settings calculated by SPArC™ are displayed in the pink areas.
If
manual
configuration is turned “on” the graph at the “Main interface” page corresponds with
the manual angle settings (beside the pink areas). The auto settings can be copied to the manual
settings, after which the auto settings can be “fine tuned” if preferred by the user.