![Sorel TDC 3 Installation And Operating Instructions Manual Download Page 31](http://html1.mh-extra.com/html/sorel/tdc-3/tdc-3_installation-and-operating-instructions-manual_1332671031.webp)
31
11.3 Solar protection functions
menus 6.3 / 6.3.1 - 6.3.5
Two solar protection variants V1+V2 and an alarm function with additional
settings are available for the hydraulic systems with solar; these are explained
in more detail below.
Caution
Danger
In variant V1 the storage tank or the swimming pool is heated up over
the Tmax value set under 10., which can lead to scalding and damage
to the system.
Caution
In variant V2 elevated standstill temperatures and the corresponding
system pressure are generated, which in some systems may lead to
damage.
The solar protection is switched off at delivery. Please consult the
operating instructions for the system components for information on
whether and what solar protection variants the system requires.
Col. alarm
If this temperature is exceeded at the collector sensor when the solar pump
is on a warning or error message is triggered. The red light
fl
ashes and the
corresponding warning appears in the display.
Col. alarm - setting range: Off/60°C to 300°C/default setting: Off
SPF variant V1
If the value “SPF T.on” is exceeded at the collector, the pump is switched on to
cool the collector. The pump is switched off if the value at the collector drops
bellow “SPF T.off” or the value “SPF Tmax stor.” is exceeded at the storage
tank or swimming pool. In systems with two storage tanks only the lower-priority
storage tank or swimming pool is used for heat dissipation.
SPF variant V2
If the value “SPF Ton” is exceeded at the collector, the pump is switched off
and not switched on again in order to protect the collector against steam blasts,
etc. The pump is only switched on again when the value at the collector drops
below “SPF Toff”.
SPF variant setting range : V1, V2, off/default setting : Off
SPF Ton setting range : from 60°C to 150°C/default setting: 110°C
SPF Toff setting range : from 50°C to 145°C/default setting: 100°C
SPF Tmax stor. setting range: from 0°C to 140°C/default setting: 90°C
Protective functions
menu 6
11
11