11
Installation
Low voltage
max. 12VAC/DC
Terminal:
Connection for:
S1
Temperature sensor 1
S1
Temperature sensor 1 (GND)
S2
Temperature sensor 2
S2
Temperature sensor 2 (GND)
S3
Temperature sensor 3
S3
Temperature sensor 3 (GND)
V1 0-10V/PWM speed controlled
output for High effi ciency pumps
- speed controlled output for 0-10V
gnd. / PWM for High effi ciency
pumps
S4 Temperature sensor 4
S4 Temperature sensor (GND)
Mains voltage
230
VAC 50-60Hz
Terminal:
Connection for:
N
Neutral conductor N
R1
Relay R1
N
Neutral conductor N
L
Mains phase conductor L
N
Neutral conductor N
R2
Relay R2
The PE protective conductor must be con-
nected to the PE metal terminal block!
Low voltage
max. 12V
Achtung
Main voltage
230
VAC
Gefahr
S4
VFS2
VFS1
CAN CAN
V1
-
S4
S3
S3
S2
S2
S1
S1
PELV
N
R2
L
N
R1
N
D. - Terminal connection diagram
Low voltage
max. 12V
Caution
Main voltage
230
VAC
Danger
On the Controller platine:
CAN1
CAN Bus connection
CAN2
CAN Bus connection