Setting System Frequency / Setting Timecode
Ch
apt
er 3 Prep
ara
tio
ns
Setting System
Frequency
This unit can record and play back video at the system
frequencies of 1080/59.94i, 50i, 29.97P, 25P, 23.98P or
720/59.94P, 50P.
Selecting the system frequency
1
Set setup menu item 013 SYSTEM FREQUENCY
SELECT MENU to “on” and press the PUSH SET
knob.
A confirmation message appears asking you whether
to change the system frequency.
2
To change the system frequency, select “on”, and then
press the PUSH SET knob.
To cancel changing the system frequency
Select “off”, and then press the PUSH SET knob.
The system frequency selection screen appears.
3
Turn the PUSH SET knob to select the system
frequency to be used.
4
Press the PUSH SET knob or the SAVE function
button (F5).
The message “Turn off/on POWER!!” appears.
5
After pressing the on/standby button and hold it down
for one second or longer to the unit into the standby
state, power it on again.
Setting Timecode
There are the following four ways of recording timecode:
Internal Preset mode:
This records the output of the
internal timecode generator, set beforehand to an
initial value. The following run modes can be
selected.
• Free Run: Timecode advances continually.
• Rec Run: Timecode advances only during
recording.
Internal Regen (regenerate) mode:
This records the
output of the internal timecode generator, initialized
to timecode following continuously upon the
timecode of the last frame of the last clip on the SxS
memory card.
External Regen mode:
This records the output of the
internal timecode generator, synchronized to an
external timecode generator. As the external input, the
timecode input to any of the following connectors can
be selected.
• TIME CODE IN connector: LTC
• SD/HDSDI INPUT connector: VITC and LTC
External Preset mode:
This directly records the input of
an external timecode generator. As the external input,
the timecode input to any of the TIME CODE IN
connector can be selected.
To record timecode after setting an initial
value (Internal Preset)
Proceed as follows with the function menu. For setting the
timecode, set TCG on page P4 TC of the function menu to
“INT” and PRST/RGN to “PRESET”.
Setting an initial timecode value
1
Press the CNTR SEL function button (F2) on the
HOME page of the function menu, and select TC.
Time data display area
Function menu