![Sony WLL-RX55 Maintenance Manual Download Page 40](http://html.mh-extra.com/html/sony/wll-rx55/wll-rx55_maintenance-manual_1329624040.webp)
1-32 (E)
WLL-RX55
1-15. Writing and Rewriting the PLD
Internal Data
This unit uses the PLD (Programmable Logic Device) that
supports the e-Production (EPR) system to write and
rewrite the internal data.
If the part listed below needs to be replaced or to be
upgraded, contact your Sony Sales Office/Service Center.
n
The part number of PLD (or ROM for PLD) in which data
is not written yet, is shown in “Section 4. Spare Parts”.
Therefore, if part replacement is required, write the data by
the following procedure.
In the case of the PLD type that runs on the program stored
in external ROM, data needs not to be written only by
replacing the part if the specific PLD only is defective.
e-Production system has the advantages shown
below.
.
To write/rewrite the PLD internal data:
1.
The standard fixture (cable) can be used.
2.
The standard software (PLD Download Tool) can be
used.
.
The PLD internal data is controlled in the Sony Database
Server under the name Project file (E_xxx_xxx_xx_xx).
.
The printed circuit board is equipped with the standard
connector (EPR connector) to write the PLD internal
data. The indication “EPR” is shown on the printed
circuit board.
Corresponding PLD
PLD
EPR connector
Project file No.
(Ref No./board name) (Ref No./board name)
IC501/AT-156
CN801/AT-156
E_000_001_40_xx
IC802 to IC806/
AT-156
*
1
IC100/DEC-146
CN700/DEC-146
E_000_001_39_xx
IC700/DEC-146
*
2
IC117/RX-89
CN300/RX-89
E_000_001_41_xx
IC300/RX-89
*
3
IC31/VA-220
CN3/VA-220
E_000_001_42_xx
IC1/VA-220
*
4
*
1: IC802 to IC806/AT-156 are the ROMs for IC501/AT-156.
*
2: IC700/DEC-146 is the ROM for IC100/DEC-146.
*
3: IC300/RX-89 is the ROM for IC117/RX-89.
*
4: IC1/VA-220 is the ROM for IC31/VA-220.
Equipment required
.
PLD download fixture
(Sony part number: J-7120-140-A)
The cable connected PC to this unit.
.
PC
A PC having parallel port.
A PC in which the PLD Download Tool software is
already installed.
For the applicable OS and the operating environment,
refer to “Download Tool Operating Instruction for
Device Programming”.
Data write procedure
Data write procedure in the PLD (or ROM for PLD) is
outlined below.
For details of data write procedure, refer to “Download
Tool Operating Instruction for Device Programming”
which is available in the same site where the PLD Down-
load Tool software is available.
1.
Prepare the Project file.
n
Download the Project file from the Sony Database
Server.
2.
Turn off the power of this unit. Connect the PC
parallel port to the EPR connector of the target board
using the PLD download fixture (cable).
3.
Turn on the power of this unit.
Start the Download Tool software and read the Project
file.
4.
Program the PLD (or ROM for PLD) with the Down-
load Tool software.
5.
Upon completion of programming, check that error
message is not displayed. Turn off the power of this
unit and back on.
Summary of Contents for WLL-RX55
Page 1: ...WIRELESS CAMERA RECEIVER WLL RX55 MAINTENANCE MANUAL 1st Edition Serial No 100001 and Higher ...
Page 64: ......
Page 126: ......
Page 134: ......
Page 140: ......
Page 154: ......
Page 164: ......
Page 184: ......
Page 194: ......
Page 196: ......
Page 230: ...Printed in Japan Sony Corporation 2004 2 08 B P Company 2004 WLL RX55 SY J E 9 968 042 01 ...