2-6 (E)
WLL-CA55
RGB Level Adjustment
4.
Set the cursor to “4 B A/D TOP” by turning the
MENU dial, and press the MENU dial.
5.
Adjust the B level by turning the MENU dial.
B level adjustment
Equipment:
Digital multi meter
Test Point:
TP410 (GND : E301)/VPR-84
board
Adjustment Point: 4 B A/D TOP (reference: 65)
Specifications:
3.60 V
±
0.02 V dc
6.
Press the MENU dial to store the adjustment value.
7.
Adjust for G level and R level in the same manner as
for B level.
G level adjustment
Equipment:
Digital multi meter
Test Point:
TP408 (GND : E301)/VPR-84
board
Adjustment Point: 6 G A/D TOP (reference: 65)
Specifications:
3.60 V
±
0.02 V dc
R level adjustment
Equipment:
Digital multi meter
Test Point:
TP406 (GND : E301)/VPR-84
board
Adjustment Point: 8 R A/D TOP (reference: 65)
Specifications:
3.60 V
±
0.02 V dc
Settings aftre Adjustment
.
Restore the VPR-84 board to the original position.
.
Perform “2-4-2. Pedestal Level Adjustment”.
*