3-7 (E)
SNC-WR632C/WR602C
3-5. Network
Trouble
Yes
No
Check FFC between CN703 on
the IF-1232 board and CN107
on the SY-416 board, and the
connection of FFC.
Yes
Is the symptom improved?
No
Uninstall Active x.
Is there any abnormality in
the appearance of CN805
(network port) on the
TM-61 board? (Bending of pin,
corrosion, discoloration, etc.)
No
Connect FFC correctly, or
replace FFC.
Yes
Can this unit be recognized by
using the SNC toolbox
1
?
No
Reset this unit to the factory
settings.
2
Update the firmware.
Yes
Reconfigure the camera settings.
Is the symptom improved?
No
Yes
Reconfigure the camera settings.
Replace CN805. If the problem
persists, replace the TM-61
board. (Refer to Section 1-4-1.)
FFC: flexible flat cable
Replace the SY-416 board.
(Refer to Section 1-4-6.)
1
The SNC toolbox can be downloaded
from the following URL.
http://www.sony.net/ipela/snc
2
1. Turn off the power of this unit.
2. Set the reset switch (S802) on the
TM-61 board to ON.
3. Turn on the power of this unit. After
waiting for 5 minutes, turn it off.
4. Set the reset switch (S802) on the
TM-61 board to OFF.