(E)
6-1
SIR-3400H / SIR-3032i / SIR-3032W
O
: Setting enabled
The reference section for common Telnet functions is section 17-2, and so this reference was omitted except for independent functions.
Setting
Default setting Operation
Remarks
Reference
LCD screen Key
Telnet Panel
section
Fan control
Off
O
For acoustic measurement and other
7-2-1
situations where silence is needed
Condensation sensor
Off
O
Based on changes in the operating environment 7-2-2
Synchronization mode
Master
O
Based on changes in the operating environment 7-2-3
Frequency type
48 kHz series
O
Fixed at 48 kHz series
8-2-1
Auto repeat
Off
O
O
For setting at hard disk empty states
8-2-2
Overwrite
Off
O
8-2-3
Trigger mode
Single
O
O
For starting recording with an external signal
8-2-4
Pre-trigger recording
Off
O
For recording signals before the trigger
8-2-5
IRIG-B timecode
On
O
For using IRIG input
8-2-6
Response characteristics
Realtime
O
O
9-2-1
of the peak indicator
Bar meter scale
%
O
O
For switching the bar meter indicator
9-2-2
LCD contrast
5
O
For adjusting the screen
9-2-3
LCD brightness
5
O
For adjusting the screen
9-2-4
Recording unit network
—
O
10-1
Setting the recording unit clock
—
O
O
Before recording
11-1
ID number
—
O
O
For adding IDs during recording
12-1
INDEX number
—
O
For adding INDEX during recording
12-2
Recording/Playback speed
1 (Normal)
O
O
For changing the speed
12-3
Number of recording channels
32 ch
O
12-4
Transmission format
S (Single-ended)
O
(Front) For the IEPE input, set to the single
12-8
ended input.
Recording memo
—
O
O
If needed during recording
12-9
Test signal
—
O
O
For recording test signals
12-11
Mark
—
O
O
If needed during recording
12-12
Changing to the address,
—
O
13-1
amount of recording media
remaining, or time display
Clearing the peak
On
O
O
13-2
indicator and over indicator
Changing the speaker
Voice
O
When the speaker or earphone playback 13-3
output
annotations
signal source is switched
Adjusting the playback volume
—
O
(Front) Based on the operating environment
13-4
Changing the AC voltage
100/120 V or
O
(Rear)
13-5
200/240 V
Save of setting values/
—
O
For making batch settings with the default
14-1
Recall of setting values
settings or with recording settings with a
current address
6. Setting and Check Items
6-1. Default Settings
c
Items described here as check items can only be checked.
6-1-1. Recording Unit Setting/Checking (Including Media Settings)
Summary of Contents for SIR-3032i
Page 4: ...SIR 3400H SIR 3032i SIR 3032W ...
Page 16: ...1 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 20: ...2 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 42: ...3 22 E SIR 3400H SIR 3032i SIR 3032W ...
Page 54: ...5 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 58: ...6 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 62: ...7 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 66: ...8 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 70: ...10 2 E SIR 3400H SIR 3032i SIR 3032W ...
Page 72: ...11 2 E SIR 3400H SIR 3032i SIR 3032W ...
Page 84: ...12 12 E SIR 3400H SIR 3032i SIR 3032W ...
Page 130: ...17 18 E SIR 3400H SIR 3032i SIR 3032W ...
Page 134: ...18 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 138: ...19 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 142: ...20 4 E SIR 3400H SIR 3032i SIR 3032W ...