
7-2
(E)
SIR-3400H / SIR-3032i / SIR-3032W
7-2. Settings
7-2-1. Fan Control On/Off (Fan Control)
This option is useful for acoustic measurements and other applications where silence is needed.
Factory setting: Off
*
For the setting procedure, see “7-1. Setting Procedure (for Main Screen)”.
<When set to On>
The fan speed is controlled based on the internal temperature of the recording unit and measuring unit.
Internal temperature
Less than 30
ddddd
C
Less than 60
ddddd
C
60
ddddd
C or higher
Fan rotation speed
Stop
Medium
High
c
.
The fan may automatically start running due to a rise in temperature.
.
The fan rotation speeds of the recording unit and measuring unit may not be synchronized in some cases.
<When set to Off>
The fan is constantly rotating at high speed.
7-2-2. Condensation Sensor On/Off (Dew Sense)
c
.
If condensation occurs the recording media and data may become damaged. In environments subject to
changes in temperature and humidity, be sure to always set the condensation detection function to On.
.
Leave a space of at least 50 mm between the right and left sides of the recording unit and any other object.
Factory setting: Off
*
For the setting procedure, see “7-1. Setting Procedure (for Main Screen)”.
<When set to On>
When condensation occurs inside the unit, such as when a cold recording unit is moved to a warm location,
the condensation warning indicator turns on (see section 18-1). When the warning indicator turns on, perform
the warmup operation while holding down the standby key, and then wait until the indicator turns off before
using the recording unit.
Warning
LCD message
Recording unit status
Remarks
indicator
—
60S to 00S
Detecting the condensation
The remaining time for detecting
the condensation is displayed
%
lit
Warming Up
Condensation was detected
Displayed during warmup
operation
600S to 000S
Dissipating condensation
Displays the remaining time until
condensation is dissipated
c
.
Once the setting is set to On, the recording unit performs detection inside the unit and cannot be used for
approximately one minute every time the power is turned on.
.
When condensation is detected and the condensation dissipation operation is being performed, be sure to
leave the power on and wait until the operation is completed.
<When set to Off>
No warnings are indicated even if condensation occurs.
7. Basic Settings (Main Screen)
Summary of Contents for SIR-3032i
Page 4: ...SIR 3400H SIR 3032i SIR 3032W ...
Page 16: ...1 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 20: ...2 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 42: ...3 22 E SIR 3400H SIR 3032i SIR 3032W ...
Page 54: ...5 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 58: ...6 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 62: ...7 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 66: ...8 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 70: ...10 2 E SIR 3400H SIR 3032i SIR 3032W ...
Page 72: ...11 2 E SIR 3400H SIR 3032i SIR 3032W ...
Page 84: ...12 12 E SIR 3400H SIR 3032i SIR 3032W ...
Page 130: ...17 18 E SIR 3400H SIR 3032i SIR 3032W ...
Page 134: ...18 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 138: ...19 4 E SIR 3400H SIR 3032i SIR 3032W ...
Page 142: ...20 4 E SIR 3400H SIR 3032i SIR 3032W ...