5-37
SEL1655G
5-5-2. Precautions for Use
• When the instruction “PUSH ENTER” as shown below is displayed
on the screen, if the “PUSH ENTER” does not disappear even after
pressing the ENTER key, press it again.
• The adjustment result is displayed on the Message area.
Click the [Message Clear] button, the histories displayed on the
Message area will be deleted.
[]
.
[]
.
[]
.
[]
[Message Clear]
button
Message area
• When the error occurs in the flange back adjustment, the Error-
CodeDisplay screen is appeared.
Please check the contents displayed on the “Possible defect/point
to check” and readjust.
Possible defect/point to check
5-5-3. Method of Starting and Finishing
* Make sure to disconnect the AC adaptor after finishing the adjustment
(including the case when stops due to an error).
* SeusEX will start when the SEL1655G_Service_Tool is started.
Procedure of Starting
1. Set the Shooting Mode of the camera to the P mode (Program
Auto), then turn the power on.
2. Start the ServiceAppLauncher.
[]
.
[]
.
[]
.
[]
Note:
If the message as shown below is displayed, confi rm that
the following a fi le is stored in “C:\Service\ErrorCodeList”
folder of the C drive.
• ErrorCodeList.xlsx
3. Select “SEL1655G” from the “Select Lens model”, and click
[OK] to start the SEL1655G_Service_Tool.
[]
.
[]
.
[]
.
[]
宖守宏孴孹學學宊
4. Click the [Connect] button, and check that the display becomes
“Connection completion!!”.
[]
.
[]
.
[]
.
[]
Procedure of Finishing
1. Click the [Dis Connect] button and check that the display be-
comes “DisConnect”.
[]
.
[]
.
[]
.
[]
2. Click the [
] button on the upper right of the main window to
finish the SEL1655G_Service_Tool.
3. Turn off the power of camera.
4. Disconnect the AC adaptor.
SYS SET