5-29
SEL1655G
11. If there is a priority zoom position in partial blur adjustment, set
the zoom position in the adjust balance select area.
Default : Balance
Wide : Emphasis on the WIDE
Tele
: Emphasis on the TELE
Note 1:
Normally, set this to “Default”.
SEL1655G_1ST_LENS_ASSY
[][][][]
Adjust Balance
Select area
12. Click the [Calculation] button of the ShimCaluc screen and the
adjustment target value is displayed in the target area.
Note 2:
Replace the back adjustment washer so that it becomes
the thickness displayed in the target area at the “5-4-1.
Partial Blur Adjustment (1st group assy)”.
Record the thickness that is displayed in the target area.
SEL1655G_1ST_LENS_ASSY
[][][][]
Target
area
13. Click the [END (Close Application)] button of the Message
Dialog screen.
14. Performe the “5-4-1. Partial Blur Adjustment (1st group assy)”
and replace the back adjustment washer so that it has the speci-
fied thickness.
15. Performe the “5-3-2. Projective Resolving Power Check” and
confirm that the partial blur is resolved.
When “Projective Resolving Power Check” is OK:
t
Partial Blur Check is complete.
When “Projective Resolving Power Check” is NG:
t
Select the “SEL1655G_MOUNT_ASSY” and perform the
Partial Blur Check/Adjustment.
16. Click the [START SHIM CALCULATION] button and the
ShimCaluc screen is appeared. Input the recorded current washer
thickness in the current area.
SEL1655G_MOUNT_ASSY
[][][][]
Current
area
17. If there is a priority zoom position in partial blur adjustment, set
the zoom position in the adjust balance select area.
Default : Balance
Wide : Emphasis on the WIDE
Tele
: Emphasis on the TELE
Note 3:
Normally, set this to “Default”.
SEL1655G_MOUNT_ASSY
[][][][]
Adjust Balance
Select area
18. Click the [Calculation] button of the ShimCaluc screen and the
adjustment target value is displayed in the target area.
Note 4:
Replace the back washer so that it becomes the thickness dis-
played in the target area at the “(1) Partial Blur Adjustment”
of “5-4-2. Resolving Power Adjustment (mount assy)”.
Record the thickness that is displayed in the target area.
SEL1655G_MOUNT_ASSY
[][][][]
Target
area
19. Click the [END (Close Application)] button of the Message
Dialog screen.
20. Performe the “(1) Partial Blur Adjustment” of “5-4-2. Resolving
Power Adjustment (mount assy) and replace the back washer so
that it has the specified thickness.
SYS SET
2020/02/04 22:49:28 (GMT+09:00)