4-1
VPL-PX20/PX30
Section 4
Electrical Adjustments
4-1. Equipment Required
.
Oscilloscope
Tektronix 2465 or equivalent
(bandwidth: 350 MHz or more)
.
NTSC, PAL, SECAM component signal generator
Tektronix TG2000
+
AVG1 (optional module)
+
AWVG1 (optional module) or equivalent
.
VG (Programmable video signal generator)
VG814 or equivalent
.
Digital voltmeter
Advantest TR6845 or equivalent
.
Luminance meter
Note:
Perform the following adjustments at least 5
minutes after turning on the power.
4-2. Preparations
4-2-1. Turning on the Power
1.
Connect the power cord and supply the power to the
unit.
2.
Check that the STANDBY LED of the control panel
lights up in red.
4-2-2. Setting the Factory Mode
1.
Check that the STATUS in the menu is ON.
2.
Exit the Menu.
3.
Press the keys in the following order:
“ENTER”
→
“ENTER”
→
“LEFT”
→
“ENTER”.
The message “Do you with to enter into the FACTORY
MODE?” will be displayed.
Select YES on the menu to set the unit into the factory
mode.
4-3. C Board Adjustments
4-3-1. R VCOM Adjustments
Turn off the menu using the STATUS OFF during adjustments.
(No shield is required.)
1.
Enter the R DRV of the device adjust by the factory
mode and check the 1 line ON/OFF signal.
2.
Adjust the
←
and
→
keys to minimize the flicker.
4-3-2. G VCOM Adjustments
1.
Enter the G DRV of the device adjust by the factory
mode and check the 1 line ON/OFF signal.
2.
Adjust the
←
and
→
keys to minimize the flicker.
4-3-3. B VCOM Adjustments
1.
Enter the B DRV of the device adjust by the factory
mode and check the 1 line ON/OFF signal.
2.
Adjust the
←
and
→
keys to minimize the flicker.
4-4. Signal Level Adjustments
4-4-1. Component Level Adjustments
1.
Connect the component signal to INPUT-A (5BNC),
and select COMPONENT with SIGNAL SELECT.
(15K Component color bar Chroma ON)
2.
Set the COLOR to 40.
3.
Connect the oscilloscope to TP612 (B OUT) on the C
board.
4.
Enter the OTHER of the device adjust of the menu.
5.
Set 06 3D GAMMA/THROUGH: 0 to 06 3D
GAMMA/THROUGH: 1.
6.
Set 07 3D GAMMA/SW: 1 to 07 3D GAMMA/SW: 0
7.
Adjust the cursor at the top of the oscilloscope to the
bar on the left side (white section).
8.
Adjust GND level to the bottom edge in the DC 0.5 V
range.
9.
Set the input signal to component color bar.
10. Select 12 YUV COL. Adjust the
←
and
→
keys so
that the levels of the right bar and the left bar become
the same.
11. Select 05 SUB HUE. Adjust the
←
and
→
keys so that
the two bars at the center become flat.
Summary of Contents for RM-PJM610
Page 153: ...9 20 9 20 A B C D E F G H 1 2 3 4 5 VPL PX20 PX30 ...
Page 161: ...9 28 9 28 A B C D E F G H 1 2 3 4 5 VPL PX20 PX30 C B SIDE SUFFIX 11 C A SIDE SUFFIX 11 ...
Page 165: ...9 32 9 32 A B C D E F G H 1 2 3 4 5 VPL PX20 PX30 Y S NF NR Y S NF NR ...
Page 177: ...Sony Corporation B P Company English 99KZ08111 1 Printed in Japan 1999 11 9 929 667 01 ...