6-19
6-2-13. EPG Service Mode
1. Summary screen
1) Turn of the main power ON.
2) On the screen after exiting all menu screens, press “ESC” on the service remote controller.
3) Press “DISP”.
4) Press “7”.
(EPG EURO)
Next Data Download Time : 14:00
Duration
: 01h30m
Gemstar Data Fail Count : 00
EPG Data Receive Err Summary
Data Start END MD CH RcvPkt TotalErr
03/31 13:00 13:30 DL 03 001853 000000
03/31 09:00 11:00 DL 03 001192 000000
03/31 08:00 08:05 HS --
000654 000000
03/31 00:00 00:00
000000 000000
03/31 00:00 00:00
000000 000000
03/31 00:00 00:00
000000 000000
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
0
1
2
3
4
012345678901234567890123456789012345678901234567
* Used when the EPG data cannot be acquired.
* The detailed screen appears every time when “DIG/ANA” is
pressed.
[Tips]
In a case where only “HS” is displayed in the MD column of the logs, the host channel has not been found.
It is necessary to check the country and postal-code settings in the user settings.
5) Press “ESC”. (Returns to the original screen)
The next download starting time for the EPG data is displayed.
Next Data Download Time: Starting time
Duration: Duration required for acquiring the EPG data
The Gemster EPG data cannot be found.
Number times of Host Scan and Schedule Download, DT models only
(Always 00 except DT model)
The 6 latest error logs when EPG data were received are displayed, with the latest one at the top.
Data
: Month/day when reception started
Start
: Time when reception started
End
: Time when reception ended
MD
: Method for acquiring the EPG data (HS: Host scanning process, DL:Downloading
process of the EPG data)
CH
: Data-receiving channel
RcvPkt
: Total number of received packages.
A number 999,999 or greater is displayed as “999999”.
Total Err
: Total errors during reception.
The sum of Hamming Err, Trans Err InvLine Err numbers indicated on the Detail screen.
A number 999,999 or greater is displayed as “999999”.
Lines 01-02
Lines 03
Lines 09-14