5. Remove the waterproof sheet (IF).
6. Remove the four precision screws, and then remove the control panel block and the microphone unit.
7. Disconnect the flexible board from the connector (CN9015) on the IF-1346 board.
8. Disconnect the flexible flat cable from the connector (CN9018) on the IF-1346 board.
Handle assembly
Microphone unit
CN9018
IF-1346 board
CN9015
Control panel block
Flexible flat cable
Precision screws
(P2 x 4)
Flexible board
Waterproof sheet (IF)