TEST MODE
HOW TO MAKE THE MEMORY STICK FOR
TEST MODE USE ONLY
1. Ready for the memory stick.
2. Make the new directly as “/Sony Reader/software” on the
memory stick.
3. Download the as follow as the files from internet site, copy to
directly.
Download files:
autorun.xml,
icon.png,
key.png,
lut.bin (If this download file’s name is different, change
to this name.)
HOW TO ENTER THE TEST MODE
1. Insert the test mode memory stick.
2. After a while, indicate the test mode menu, enter the test mode.
1. Test Panel
1. While the machine selected tab “Test Panel” in test mode menu,
press the
[ENT]
button, or press the
[1]
button.
2. Screen is changed to the Test Panel.
3. The display is changed so bellow with each time of pushing
the
[>]
button or
[<]
button of
[PAGE]
.
4. It’s back to TEST MODE MENU when the
[MENU]
button.
5. After the end of test, a display of Test Panel on TEST MODE
MENU is changed to “Done” from “Not Yet”.
2. Check All Key
1. In the state that a Check All Key tab of TEST MODE MENU
is selected, push the
[ENT]
button or
[2]
button.
2. The screen is switched into the Check All Key state.
3. The display invert when each button is pushed, and the display
is back to the all button.
4. After the end of test, a display of the right side of Test Panel
on TEST MODE MENU is changed to “Done” from “Not
Yet”.
3. Update Waveform
In this mode, it is possible to confirm the variation of LUT (Look
Up Table) and rewrite. The change of the LUT is required when a
INK INDICATOR ELEMENT, MAIN BOARD and FLASH ROM
(IC1611) are replaced. However, a INK INDICATOR ELEMENT
is different from parameter by each lot number, therefore, rewriting
is not required if the lot number is the same. The lot number is
written on the label on the flexible board.
1
2
3
4
5
6
7
8
9
0
UP
ENTER
DOWN
LEFT
RIGHT
MENU
MARK
SIZE
VOL-
VOL+
PREV
NEXT
NEXT
PREV
1. The current LUT version displayed at the right side of Update
Waveform on TEST MODE MENU.
2. In the state that a Update Waveform tab is selected if it is
pushed the
[ENT]
button or
[3]
button, it starts rewriting LUT
version.
NOTE:
It is necessary to match the LUT version to the version in
elation to the lot number of the INK INDICATOR
ELEMENT. Refer to Technical News about details.
3. After a few minutes (about 10 seconds), the screen display is
refreshed, a LUT version display of the right side of Update
Waveform on TEST MODE MENU is refreshed.
4. Reset Screen Lock
The screen lock can be compulsorily released.
1. The current state of screen lock and the password are displayed
on the right side of Reset Screen Lock of TEST MODE MENU.
2. In the state that the Reset Screen Lock tab of TEST MODE
MENU is selected, push the
[ENT]
button or
[4]
button.
3. The display on the right side of Reset Screen Lock is changed
to “Off-0000”, so Screen Lock is unlocked .
5. Power Off
1. In the state of a Power Off tab of TEST MODE MENU, push
the
[ENT]
button or
[5]
button.
2. After a while, the screen display is changed white, so power is
turned off.
WHITE
LIGHT GRAY
DARK GRAY