7 (E)
1
POWER switch
This is for turning the power to the unit on and off.
When turning on the power, press the ON side.
To turn the power off, press the OFF side. Power
supply will then stop automatically two to twenty
seconds afterwards when the operation being
processed is finished, and the transfer returns to the
original position. When the power is turned off, all
indicators on the display panel go dark.
2
Display panel
The operating conditions, status, etc., of the system
appear here. Using this panel, initialization of the
system, and menu operation for checking the system
configuration and hours meters are also possible.
For details, see “Display Panel” on page 8(E).
3
IN/OUT port
This port is for loading and removing cassettes. You
can mount a magazine containing up to five cassettes
in a port of the DMS-B80L/B110S or in the upper or
lower port of the DMS-B150L/B210S. Two types of
magazines are available: for S cassettes and for L
cassettes.
Care must be taken to load the cassettes in the right
direction.
For details, see “IN/OUT Port” on page 9(E).
4
BREAKER switch
Shuts down the power supply in an emergency. Keep
in the
I
position. In an emergency, such as fire, set to
the
a
position.
Set the BREAKER switch to the
I
position after
removing the cause of emergency.
Use of this switch puts load on the transfer
mechanism. Do not use it except in an emergency.
Warning
In an emergency, be sure to set the BREAKER switch
to
a
position to turn the power off.
5
Transfer check window
The position of a transfer may be checked through this
window.