Configuring Action Settings
C
h
a
p
te
r 4
A
ppli
c
at
ion S
e
ttings
7
Click [OK].
The event/alarm action is created.
5
Click [Apply].
The event/alarm action is saved.
For details on how to view the schedule, refer to
Items of Schedule Screen” (page 73)
.
Setting Items of New Action Dialog Box
(Event/Alarm Action)
This dialog box is displayed by selecting [Action] from the
tree in the Schedule Configuration screen, and then
clicking [New Action].
After configuring each item, click [OK].
Screen example: When recurrent event/alarm
action:
A
Schedule Action and Event/Alarm Action
Select the type of event/alarm action to configure.
The setting items vary depending on this selection.
B
Schedule
Enter the name of the event/alarm action. It can be up to 32
characters long.
C
Enable
Select the check box to enable this event/alarm action.
D
Schedule
The settings differ depending on whether you are
configuring a recurrent event/alarm action or an event/
alarm action for a specific date and time.
When recurrent event/alarm action:
Select the check boxes for the days you want to run the
event/alarm action, and configure a start time and end
time for the event/alarm action.
The range that can be specified is 00:00:00 to 23:59:59
(hours/minutes/seconds).
When event/alarm action for a specific date
and time:
Configure the start date and time and end date and time
to apply the event/alarm action.
E
Action Duration
Configure the duration for the action.
Action Start
This displays the timing for starting the action.
This item cannot be changed.
Stop Action
Select the timing for ending the action.
From Alarm Start
This ends the action at the point in time a specified
time elapses after the alarm started.
When this is selected, enter the period for after the
alarm starts within the range of 1 to 3,600 seconds.
From Alarm End
This ends the action at the point in time a specified
time elapses after the alarm ends.
When this is selected, enter the period for after the
alarm ends within the range of 1 to 3,600 seconds.
No Definition
The timing to end the action is not specified.
F
Server
Select the remote server.
This item is displayed in the case of a client.
G
Event
Configure the event that will be the trigger for the action.
Camera
Select the check box of the input pin to be the action
trigger.
I/O Device
Select the check box of the input pin to be the action
trigger.
The input configured for each camera and I/O device
is displayed in the list. For the input pin settings, refer
to
“Configuring Motion Detection Settings” (page 59)
and
“Configuring Sensor Inputs” (page 76)