2-1 (E)
MAV-555
Section 2
Service Overview
3.
Loosen the two screws (with drop protectors) and
remove the top panel A.
4.
Loosen the two screws fixing the ornamental panel at
the top. Remove the two screws fixing the ornamental
panel at the bottom as shown, and remove the orna-
mental panel.
2-1. Cleaning the Air Filter
There are filters at three locations in the unit; one at the
back of the meter panel, one at the back of the front panel
and the third at the back of the blank panel.
If dirt accumulates on the filters, ventilation will be
blocked and heat will build up inside the unit, which may
cause the unit to fail.
Therefore, the filters should be cleaned periodically.
n
For details of filter replacement, refer to the MAV-555
maintenance manual volume 1.
Cleaning
1.
Turn off the main power.
2.
Remove the control panel or blank panel.
Control panel
or
blank panel
Screws (with drop protectors)
Top panel A
+
B3
x
6
+
B3
x
6
Ornamental
panel
+
B3
x
6