1-15 (E)
MAV-555
1-9-5. Setting the Setup Level
n
This setting has the meaning in the 525/60 (NTSC) mode
only. This menu does not appear in the 625/50 (PAL)
mode.
1.
Set the switch S300-1 on the EM-1 board to the ON
position.
2.
Turn on the main power.
3.
Open the [701
.
IN SETUP RMV R1] display from the
setup menu.
4.
Press the VIDEO/MENU knob once.
5.
Turn the VIDEO/MENU knob and select “on” if the
system is used in an NTSC area or “off” if the system
is used in a PAL area.
6.
Select menu Nos. 702 to 704 in the same manner.
Setup menu
U.S.A. or
Europe
Japan
Canada
701 IN SETUP RMV R1
on
off
off
702 IN SETUP RMV R2
*
on
off
off
703 OUT SETUP P1
on
off
off
704 OUT SETUP P2
*
on
off
off
*
: This message appears when the BKMA-510 is installed.
7.
Turn off the main power.
8.
Set the switch S300-1 on the EM-1 board back to the
OFF position.
1-9-6. Setting the Network
1.
Set the switch S300-1 on the EM-1 board to the ON
position.
2.
Turn on the main power.
3.
Open the [220 IP ADDRESS] display from the setup
menu.
4.
Press the VIDEO/MENU knob once and open the
SubMenu.
5.
Turn the VIDEO/MENU knob and select which byte
you want to modify. Press the VIDEO/MENU knob
once.
6.
Turn the VIDEO/MENU knob and set the address.
Press the VIDEO button once.
7.
Set the other bytes in the same way.
8.
Press the SET button.
9.
Turn off the main power.
10. Set the switch S300-1 on the EM-1 board back to the
OFF position.
1-9. Settings upon Completion of Installation
701
.
IN SETUP RMV R1
on
220 IP ADDRESS
SubMenu
220 IP ADDRESS
192
BYTE 1
220 IP ADDRESS
0
BYTE 4
220 IP ADDRESS
10
BYTE 4