– 73 –
KP-FR43M31/FR43M91
RM-GA001
SECTION 4
ADJUSTMENT
4-1. HV REGULATION ADJUSTMENT (D Board)
When replacing the following components marked with on
the schematic diagram, always check hold-down voltage and
if necessary re-adjust.
: RV8002
: R8014, R8015, R8017
IC8005
PH8003
T8001(RHT)
HV block, D board
1. Connect a HV static voltmeter to the unconnected plug
of the highvoltage block. (Fig.4-1)
2. Videio input with all white signal.
Set “FULL” mode & “Personal”.
Set the PICTURE (max.) and BRIGHTNESS (min.)
settings.
3. Power on the set.
4. Confirm that the static voltmeter reading is 31.0 ± 0.2 kV.
5. If not, adjust with RV8002 to the specified value.
6. After adjustment, apply sufficient amound of RTV KE490
on the RV8002. (Fig.4- 2)
Note: This adjustment within 1 minute-3 minutes after
powrering.
Fig. 4-1
Fig. 4-2
4-2. +B MAX VOLTAGE CONFIRMATION
The following adjustments should always be performed
when replacing IC6801, R6809
1. Supply 220V AC to variable autotransformer.
2. Receive dot signal pattern and set the PICTURE and
BRIGHTNESS setting to their minimum.
3. Confirm the voltage of TP+B 135V is less than
137.0 Vdc.
4. If step 3 not satisfied, replace IC6801 and repeat above
steps.
4-3. +B OVP CONFIRMATION
1. Supply 220V AC to variable autotransformer.
2. Turn on set.
3. Receive dot signal pattern.
4. Set the PICTURE (minimum) and BRIGHTNESS
(minimum) settings.
5. Turn off set.
6. Separate R6809 (D Board) from +135V.
7. Apply external 160V ± 1VDC to open end of R6809.
8. Turn on set.
9. Confirm the LED blin ks 3 items.
10. Turn off the SET.
Then nount the R6809 corrlctly.
Remove the cap off from
the unused terminal and
connect a HV static
voltmeter there.
RTV KE490
RV8002
Summary of Contents for KP-FR43M31
Page 126: ... 153 KP FR43M31 FR43M91 RM GA001 TL1431CZ AP STK394 510 n IC ...
Page 165: ...2 ...
Page 200: ...2 ...