![Sony JunboTron JME-SA200 Operating Instructions Manual Download Page 45](http://html.mh-extra.com/html/sony/junbotron-jme-sa200/junbotron-jme-sa200_operating-instructions-manual_400664045.webp)
Adjustment
45
6
Press the ENTER button.
The unit recalls the factory data. SAVE and CANCEL appear at the
bottom of the display window.
* S C R E E N U N I T / F - D A T A *
B A C K G R O U N D : W H I T E
[ F I X E D ]
U N I T
X : 4 Y : 3 Z : 1
F 2 F 4
S A V E C A N C E L
7
Press the F2 button.
The factory data is saved. While saving the data, the remaining time
flashes at the bottom of the display window.
To cancel saving the factory data
Press the F4 button.
* S C R E E N U N I T / F - D A T A *
B A C K G R O U N D : W H I T E
[ F I X E D ]
U N I T
X : 4 Y : 3 Z : 1
S A V I N G 1 0
To recall the factory data on another unit
After saving the factory data or pressing the F4 button, the previously
selected unit flashes.
To recall the factory data on another unit, repeat from the unit number
assignment (step
4
).
To clear the assigned unit number, press the MENU button and repeat
from step
3
.
Notes
• Once you have reset the luminance of a specified unit to the factory data,
you can no longer recall the luminance level you set before.
• If you press the
V
button during the luminance adjustment in step
5
, the
cursor moves to the UNIT Z position and the previous luminance
adjustment level is restored.
• If you do not press the F2 or F4 button but press the MENU button in
step
7
, the previous luminance adjustment level is restored.
Remaining time