3-13
SNC-RZ30N/RZ30P (E)
3-7-2. Operation failure of tilt
Trouble 1
Trouble 2
No
Yes
Is 23-pin of the
flexible flat cable (FA1)
correctly connected?
Connect 23-pin of FA1
correctly.
Operation failure of tilt
Check the signal around the
connector, then replace the MDR-20
board or FA1.
No
Yes
Yes
Does the unit
move smoothly when it is
moved in pan direction (right and left)
by hand in the state of
power off?
After readjusting
the pan and tilt, does the tilt
operate smoothly?
Reassemble the unit.
No
Replace the tilt motor.
Tilt operation is not
smooth.
Normal