2-7
SNC-RZ30N/RZ30P (E)
2-2. Initialization of D, E, F, B, C Page
Data
1. Initializing the D, E, F, B, C Page Data
For camera micro processor: Page D, E, F
For VISCA micro processor: Page B, C
m
.
If “Initializing the D, E, F, B, C Page Data” is per-
formed, all data of the D page, E page, F page, B page
and C page will be initialized. (It is impossible to
initialize a single page.)
.
If the D, E, F, B, C page data has been initialized,
“Modification of D, E, F Page Data” and all adjustments
need to be performed again.
.
NTSC model : SNC-RZ30N
PAL model
: SNC-RZ30P
Initializing Method
.
Whole data writing in a camera micro processor
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 00, and set data: 55 ((NTSC)
or data: 51(PAL). And select page: 6, address: 01 and
set data: 55 (NTSC) or data: 51 (PAL).
3) When page: 6, address: 02 and data: 01 is indicated on
the screen, data writing is completed.
.
Whole data writing in a VISCA micro processor
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 00, and set data: 55 ((NTSC)
or data: 51(PAL). And select page: 3, address: 01 and
set data: 55 (NTSC) or data: 51 (PAL).
3) When page: 3, address: 02 and data: 01 is indicated on
the screen, data writing is completed.
2. Modification of D, E, F, B, C Page Data
If the D, E, F, B, C page data has been initialized, change
the data of the “
*
4” address shown in the following preset
data tables by manual input.
Modifying Method
1) Before changing the data, select page: 0, address: 01,
and set data: 01.
2) New data for changing are not shown in the tables
because they are different in destination.
When changing the data, copy the data built in the
same model.
n
If copy the data built in the different model, the
camera may not operate.
3) When changing the data, press the PAUSE button of
the adjusting remote commander each time when
setting new data to write the data in the non-volatile
memory.
4) Check that the data of adjustment addresses is the
initial value. If not, change the data to the inital value.
5) After completing “Modification of D, E, F, B, C Page
Data” select page: 0, address: 01, and set data: 00.
Also perform all adjustments.
Summary of Contents for IPELA SNC-RZ30N
Page 1: ...NETWORK CAMERA SNC RZ30N SNC RZ30P SERVICE MANUAL 1st Edition ...
Page 10: ......
Page 68: ......
Page 90: ...6 6 SNC RZ30N RZ30P E Chassis Block 2 301 302 303 303 303 304 305 ...
Page 102: ......
Page 104: ......
Page 118: ......
Page 126: ......