3-10
ILCE-7M3/7M3K
3-10. ANTI SHAKE UNIT SECTION
Note 2:
The imager may get structurally damaged from the
influence of static electricity. Protect against static
electricity and similarly take care when handling
the MOS IC.
Also, keep the receiver of the imager away from
debris and intense light.
Note 1:
of cleaning the OLPF.
463
457
455
451
451
460
461
459
462
460
456
452
453
458
not supplied
(All mounted parts and IS-1033 complete board are not supplied,
but they are included in mecha device service (5500) (Ref. No. 401).)
(Note 2)
front side
rear side
454
(Note 1)
not supplied
Ref. No.
Part No.
Description
Ref. No.
Part No.
Description
451
4-597-750-01
IM IMAGER FIX SHAFT (5300)
452
4-558-386-02
IM PLATE (5000), GLASS RETAINER
453
4-575-430-01
IM MASK PLATE (5100)
454
1-856-671-11
OPTICALFILTERBLOCK (OFB-01-106) (Note 1)
455
4-576-761-02
SHEET (5100), SPACER
456
1-982-424-11
ISL-2009 FLEXIBLE BOARD
457
1-982-425-11
ISP-2008 FLEXIBLE BOARD
458
4-685-117-01
AS GRAPHITE SHEET BTM (5300)
459
4-725-468-01
IM SHIELD SHEET (5400)
460
4-685-636-02
IM RADIATION SHEET B (5300)
461
4-724-002-01
IM RADIATION SHEET A (5400)
462
4-688-448-02
IM RADIATION SHEET C (5300)
463
A-2166-305-A TEX-5300
SYS SET