1-2
ILCE-7M3/7M3K
1-2. PRECAUTION FOR REPLACEMENT
OF THE MECHA DEVICE SERVICE
(IMAGER)
Capture the data to PC from CD-ROM supplied with the mecha
device service when it is ordered.
Write the captured data in the set using “Imager DRA Data Write”
in the ADJUST tab of the Adjust manual.
After all adjustment items have been completed, execute “Phase
Difference AF Check” on the SERVICE tab of the Adjust manual.
1-3. PRECAUTION FOR REPLACEMENT
OF THE MECHA DEVICE SERVICE
(GYRO SENSOR) OR THE GY-1014
BOARD
Adjustment values of each gyro sensor are stored on the SY board.
Therefore, when the mecha device service or the GY-1014 board has
been replaced, write the sensitivity values of gyro sensor.
When replacing mecha device service:
1. Read the sensitivity values of P and Y written on the gyro data
label of CD-ROM supplied with the mecha device service when
it is ordered, and memorize it.
Gyro Data
P Y
Gyro Data Label
P: Pitch Sensitivity Value
Y: Yaw Sensitivity Value
CD-ROM
Note
: The Pitch/Yaw Sensitivity Value is written by 1-digit number.
2. After the mecha device service has been replaced, execute “Set
Gyro Sensor Data” on the ADJUST tab by using the Adjust
manual to write the adjustment values.
When replacing GY-1014 board:
1. Read the sensitivity values of P and Y written on the repair parts,
and memorize it.
SE7701
P Y
Direction mark
P: Pitch Sensitivity Value
Y: Yaw Sensitivity Value
GY-1014 BOARD
Note
: The sensitivity value is written only on repair parts.
The Pitch/Yaw Sensitivity Value is written by 1-digit number.
2. After the GY-1014 board has been replaced, execute “Set Gyro
Sensor Data” on the ADJUST tab by using the Adjust manual to
write the adjustment values.
1-4. NOTES FOR REPLACING THE EVF
DISPLAY DEVICE (LCD902) OR THE
SY-1086 BOARD
Adjustment values of each EVF display device (LCD902) are stored
on the SY board.
Therefore, when the LCD902 or the SY board has been replaced,
write values of brightness and white balance.
When LCD902 is replaced:
1. Read the QR code printed in EVF element (LCD902) using with
“QR_Code_Reader_Ver1.0_x64”.
2. Make sure the value from the read value as shown below, and
memorize it.
(Example) In case the read value is “1958817021A”
195 = Brightness value
172 = White balance value
Brightness value
White balance value
1
2
3
4
5
6
7
8
9
10
11
1
9
5
8
8
1
7
0
2
1 A
195
172
3. After the LCD902 has been replaced, execute “EVF Data Input”
on the ADJUST tab by using the Adjust manual to write the
adjustment values.
When replacing SY board (In case adjustment values can
be read):
1. In case the unrepaired unit starts and adjustment values can be
read by using the Adjust manual, execute [READ and SAVE
(Restore Data)] of “Restore Data” on the DATA tab.
2. After the SY board has been replaced with a SY board for repair,
execute [Load and Write] of “EVF Data Input” on the ADJUST
tab of the Adjust manual to write the extracted data to the unit.
When replacing SY board (In case adjustment values
cannot be read):
1. Read the values of brightness and white balance from EVF ele-
ment (LCD902) as with “When LCD902 is replaced”.
2. Execute “EVF Data Input” on the ADJUST tab using with Adjust
manual.
SYS SET