1-2
ENGLISH
ENGLISH
HXR-MC1/MC1P
1-3-3. Self-diagnosis Code Table
C
C
C
C
E
E
E
E
Block
Function
0
4
1
3
1
3
3
2
2
0
6
1
6
1
9
4
Detailed
Code
0
0
0
1
0
2
6
0
0
0
1
0
1
1
0
0
Symptom/State
Non-standard battery is used.
“Memory Stick Duo” is unformatted.
“Memory Stick Duo” is broken.
Access error
Difficult to adjust focus
(Cannot initialize focus)
Flash memory data are rewritten.
Zoom operations fault
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
initialization of the zoom lens occurred
simultaneously.
Fault of writing to or erasing the flash
memory
Self-diagnosis Code
Repaired b
y:
Note:
Refer to Service manual ADJ (“1-3. DESTINATION DATA WRITE”).
Correction
Use the InfoLITHIUM battery.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Remove the power source.
Reconnect it again and operate your camcorder again.
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin
1
,
2
of
CN5202 on the LD-235 board). If it is OK, check the focus
motor drive IC (IC5201 on the LD-235 board).
Make flash memory data correct value. (Note)
Inspect the lens block zoom reset sensor (pin
wf
of CN5202 on
the LD-235 board) when zooming is performed when the zoom
lever is operated, and the zoom motor drive circuit (IC5201 on
the LD-235 board) when zooming is not performed.
Check both C : 32 : 60 and E : 61 : 10 of the self-diagnosis code.
Inspect the flash memory (IC2101 on the VC-546 board).