57
FRONT OF SCREEN
0: UPPER SENSOR
1: LEFT SENSOR
2: RIGHT SENSOR
3: LOWER SENSOR
3
2
0
1
• ERROR CODE SCREEN DISPLAY
Error codes in normal (customer) mode are not
displayed. You must enter PJE service mode to see
the error code.
PJE 125 213 60
ERR
Color:
0 = Green
1 = Red
2 = Blue
Error Code:
(See Error List)
(Blue Sensor 3 Low Output)
In service mode, the error will be displayed in
text format.
ERROR B
LO LEVEL S3
3
2
0
1
SENSOR POSITIONS
2-16.AUTO REGISTRATION DIAGNOSTICS
The TEST service item (PJE #136) can be used to determine if a sensor or sensor amplifi er is working properly. It can also be used to check pattern
positions.
DISPLAY/
LOOP
CS/ZL
COLOR
ACTION
(0)
0
0
Normal calibration (no diagnostics).
(0)
X
X
Performs one adjustment cycle, then
displays average peak voltages for the
specified CS/ZL and Color.
(0)
3
3
Does nothing (can't display more than one
CS/ZL or Color at a time.)
1
X
X
Adjusts specified CS/ZL and Color
until a key is pressed. Useful for
measuring signals with oscilloscope.
Color:
0=Green, 1=Red, 2=Blue, 3=All
CS/ZL:
0=None, 1=Cent/Skew, 2=siZe/Lin, 3=Both
Display/Loop
: 0=Display,
1:Loop
133
S0: 2.04 S1: 1.86
S2: 1.98 S3: 2.23
Sensor 0 peak voltage = 2.04 V, etc.
S0
S3
S2
S1
Summary of Contents for Hi-Scan KP-51WS520
Page 17: ...KP 46WT520 51WS520 57WS520 KP 46WT520 51WS520 57WS520 17 WIRE DRESSING 46 Cabinet 46 HB ...
Page 20: ...KP 46WT520 51WS520 57WS520 KP 46WT520 51WS520 57WS520 20 HV Wire HV wire HV Wire HV wire ...
Page 25: ...KP 46WT520 51WS520 57WS520 KP 46WT520 51WS520 57WS520 25 DY Sub DY B DY G DY Excess wire ...
Page 29: ...KP 46WT520 51WS520 57WS520 KP 46WT520 51WS520 57WS520 29 AR Sensor Excess Wire AR Sensor ...